Material
One (1) PB130 -230 po wer base
One (1) floor sensor (for floor h eating control mod ules AF
and F )
One (1) wall plate (optional, in cert ain countries)
Power Base
PB130-230
Installation Instructions
Technical Specifications
Model
: PB1 30-23 0
Supply
: 23 0 VAC , 50 Hz
Lo ad
: 16 A maximum (resistive onl y)
Power
: 3680 W atts (NI) @ 230 VAC
C erti fica tio n
: E N607 30-2-9 / EN5 008 1-1 / EN50 082-2
St orage
: -20°C to 50°C
Protect ion
: C lass 2
Pr otec tion de gree
: I P 20
Automatic action
: Type 1. B
Environment
: Normally polluted
Size (H • W • D)
: 75 x 75 x 14 mm (7 .5 x 7.5 x 1.4 cm)
NO TE:
T he termin als are designed to handle a wire size
between 0 .33 to 3.1 mm
2
.
TWO (2) YEAR LIMITED WARRANTY
This produ ct is guaranteed ag ainst workmanship defects for a two -year period following
the ini tial date o f purchase. During this period, HandyHeat
. will re pair or
replace, a t our option and without char ge, any def ective p roduct which has been us ed
under normal conditions.
The warranty does not cover delivery co sts and do es n ot apply to products poorly
installed o r randomly damaged f ollowing i nstalla tion. This warranty cancels and
replaces any ot her manu facturer's e xpress or implied warranty as well as any other
company c ommitment.
HandyHeat cannot be held liable for related or rand om dama ges f ollowing
the installation of th is prod uct. The defective p roduct as well as t he p urchase invoice
must be r eturned to the p lace o f purchase or ma iled, prepaid and insure d, to the
nea rest locat ion.
If you have any question s concerning the inst allation of the
PB130-230 power base , call our techn ical support team at:
Introduction
T he PB130-230 power base is designed to power aDVTH13x
Series con trol mo dule. The resistive load must not exceed
3680 watts (NI) @ 230
VAC (16 A).
Installation Guidelines
Tu rn off power to the heating system at the main power pa ne l
to avoid e le c trical shoc k. Installa tion s h o u ld be ca r rie d out by
a n elec tr ic ia n.
All work must conform to the most recent country’ s regu la-
tions for electrical inst allations an d wiring.
Th is thermost at should be connected on a circuit equipped
with a fuse or a circuit breaker . It must be installed on a certi-
fied el ectrical box.
Fo r a new inst alla tion, choo se a lo ca tion about 1.5 m (5 ft.)
above the floor.
The thermost at must be installed facing the heating system.
T he thermostat must be installed on an inside wall.
Avoid locations where there are air dra fts (top of stairca se, air
outlet), dead air spo ts (b ehind a door), d irect sunl ight or con-
cealed chimne ys or stove pipe s.
Remove the scre w holding the con-
trol module to the power base.
Note that the scre w can not be
completely re moved.
If yo u have a wall plate
: Before making
the co nnections, make sure that the base
covers t he ele ctrical bo x entirely. If n ot,
inse rt the cover pl ate on rear of the base.
NOTE:
T he cover plate can be used to cover
the pla te for aesthetics.
Connect the wires:
•
Power
:
Terminals 1 and 5
•
Lo ad
:
Terminals 2 and 4
•
F loo r sensor
:
Terminals 6 and 7
(no pola rity needs
to be respected )
Do n ot pla ce the floor sensor
directly next to an element but
rather, for maximum
performance, the floor sensor should be ce ntered be tween the wire s
in the mat (80°C max.). The tem pera ture sensor wire ca nnot la y
across any heater wires.
If the lo ad is driven thro ugh a
contactor, a snubber must be installed
at the con tactor’s co il termina l. See
wiring dia gram below.
Push wires into th e electrical box an d secure
the base to the electrical box anchora ge.
Th e head of the screw must be less
than 2mm th ick.
Con figure the switches (if neces-
sary) a nd install the co ntrol mod-
ule o nto the p ower base (r efer to
the user gu ide).
Return power to the heating system .
DVK-130-001-A