background image

TROUBLE SHOOTING

Problem  

Check

Action

No air blows even  
if hands are inserted

Are the display indicators lit?
Is the power switched on?
Are you putting your hands all the way into 
the unit?

Turn the ground-fault circuit breaker on
Turn the power switch on
Put hands all the way into the unit

Machine continues working 
when hands are removed, 
screen shows ‘E2’

Is there any dirt or foreign body on the sensor?

Swith off the power button and once the power light has gone off 
remove the dirt or foreign body from the sensor . Once finished, 
switch the power back on .

No hot air

There is an inbuilt heat sensor in the unit – is 
there any dirt on the heating sensor?
Has the fuse inside the terminal box blown?

Is the ambient temperature higher than 20°C?
Switch off the power, remove the front cover . There is a terminal 
box inside, take the cover off this . Check whether the fuse inside 
the terminal box has blown .

Airflow is too low

Is the speed button set to low level?

Turn the speed button to the high setting

If the above actions do not work, turn off the power and call your dealer to inspect and repair your unit, if necessary . 

7

TROUBLE SHOOTING • ELECTRICAL SCHEMATIC

Power

switch

Wiring

terminal

blocks

Fuse

Fuse

Power

Control PCB

Motor

Display

PCB

Sensors 

receiving PCB

Sensors 

start PCB

Temperature 

probe

Temperature 

probe

Thermal protection 

switch

Thermal 

circuit breakers

Heaters

Compensation

probe

ELECTRICAL SCHEMATIC

Status

Introductions

Status

Introductions

Solution

Power  

indicator light

Lit

Power on

Off

Power not supplied

Check external power source, close 

the power switch

Master board fuse 

blown

Repair fuse

State indicator 

light

Off

Machine not in use

Flashing light

Motor fault, it won’t 

operate nomally

Check motor connecting wires and 

the clear any foreign objects

Used for longer  

than 25s

Clear workspace of foreign objects, 

restart to work

Timing digital 

tube

Digital Readout

E1

Motor fault, nomally

E2

Run time longer  

than 25s

Clear workspace of foreign objects, 

restart to work

E3

Incorrect voltage/power 

surge

E4

Voltage drop

Check the power supply circuit

E5

Machine temperature 

higher than 80°C

E6

Master board tempera-

ture is higher than 80°C

Ensure the air inlet and outlet are 

clear of foreign objects

E8

Fan fault

Check the fan sensor connection

Summary of Contents for gorillo ultra

Page 1: ...User Manual...

Page 2: ...seconds To continue drying withdraw hands and re insert them SPECIFICATIONS Rated voltage AC220 240V Motor Brushless DC motor Input power 1650 2050W Induction method IR blocking Wind velocity 95m S P...

Page 3: ...Ensure the unit has a reliable earth connection Do not install connected to a power supply This hand dryer must be installed by a qualified electrician If the power cord is damaged it must be replaced...

Page 4: ...r Hand drying area Unit Drain hose Drainage tank Full level indicator Air inlet panel Drying time and fault display Fan speed button Manual power switch Lock Switch door plate Drain outlet Lock Air in...

Page 5: ...ying function will start automatically Pull them back slowly allowing the water to blow away Repeat if necessary Pull hands out completely Place wall sticker in a prominent position the front of the u...

Page 6: ...anel Pull the air filter out by the handle 1 Cleaning the air filter Beat it lightly by hand or use a vacuum cleaner You can also use a soft brush to brush off the dust 2 Re attach insert the correct...

Page 7: ...rn off the power and call your dealer to inspect and repair your unit if necessary 7 TROUBLE SHOOTING ELECTRICAL SCHEMATIC Power switch Wiring terminal blocks Fuse Fuse Power Control PCB Motor Display...

Page 8: ...when the floor is cleaned Ensure there is at least 150mm clear space below the machine either to the floor or other objects in the location It is recommended that a minimum distance of100mm should be...

Page 9: ...crete reinforce it prior to installation Place the drilling template onto the wall and drill holes Place rawplugs into the holes and screw on mounting plate as shown 1 Remove the drain tank and air fi...

Page 10: ...sits flush to the wall Install the safety screws x 2 NOTE the unit must be installed with the safety screws or it will be unstable 1 Replace the air filter Carefully push the air filter up into the un...

Page 11: ...Unit 1 Mounting plate 1 5mm Expansion pipe 6 5 x 30 Self tapping screws 6 User manual including Packing List and Warranty Card 1 Method of use figure 1 Drilling template 1 11 PACKING LIST...

Page 12: ...www handydryers co uk...