background image

13cm

125-135cm

1

2

4

~

Motor

Heat switch

Ion
generator 

Heater

BKR

sensor board

Power board

flat cable

Wire drawing

3

Please note:  

There must be a minimum of 1.1 meters allowance from the floor to the 
base of the hand dryer. 

Installation instructions

1.Use template to mark the required position on the wall.  Do not mount

the Dillo over a shiny surface as it will activate the sensor.

2.Do not place anything in the area where the sensor is located.

3.Drill 4 holes as per the template.  Place the raw plugs in the holes.

4.Loosen the screws from the Dillo and remove the cover.

5.Position the unit upon the template and secure with the 4 screws.

6.Replace the cover and secure.

Usage instruction

Place hands under dyer.  The unit will start automatically and shut off after 
50 seconds.  This can be re-activated immediately if required.