Operating Manual
Double Seal Valve
75100 / 75200
_^|MTRNMMKMM|bk
==
==
^äÄÉêí=e~åÇíã~åå=^êã~íìêÉåÑ~Äêáâ=dãÄe=C=`çK=hd=
2011-05-31
9 / 19
4.3 Technical Data
Product range
Materials
Stainless steel 1.4404
Seals
EPDM, FDA proof
Surface (Ra)
≤
0.8 µm
Nominal sizes
DN 40, 50, 65, 80, 100
Other parts
Materials
Stainless steel 1.4301
Surface Ground,
matt
Production / CIP
Flow media
Liquids and gases, (non toxic, less aggressive)
Operating pressure (type 75200)
10 bar; for all DN nominal sizes
Operating pressure (type 75100)
8.0, 6.5, 5.0, 3.0, 2.0 bar; for DN 40, 50, 65, 80, 100
Operating temperature
0 - 95°C / 140°C
Control air (for actuator)
6 - 8 bar,
6/4
75100
75200
DN
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
Lift
[mm]
40
90 62 352 38 41 30
50
100
74
365
50
47
36
65
115 90 400 66 55 48
80
130
111
400
81
69
48
100
140 130 410 100 79 48
4.4 Valve Housing Executions
The double seal valve is available with different standard housing designs (2-4 connections).
751..
752..
No.
..01 ..02
No.
..01 ..02 ..03 ..04