Spray ball
09513, 09514, 09515, 09516, 09517
BA_009500.03_EN
3 / 6
Albert Handtmann Armaturenfabrik GmbH & Co. KG
2019-03-05
3
Delivery, Completeness, Storage
Pos : 9. 2 /T ec hnis che D okument ati on/Betriebs anl eit ung en/ Li ef erung und Leist ung, Lager ung/Li ef erung und Leist ung, Lager ung @ 0\ mod_1215178430359_20. doc x @ 316 @ @ 1
•
Check the data of the delivery note for factual correctness and the material for
completeness. We regret that money cannot be refunded after purchase.
•
Always check the material for transport damages. Possible damages have
to be informed immediately.
•
Store the material in a dry place and if possible in its original packaging.
Pos : 10 /T echnisc he Dokumentation/Ü bers chrift en/ 1./M ont age, Betrieb, Wart ung ( 4) @ 0\ mod_1215179594328_20.doc x @ 364 @ 1 @ 1
4
Installation, Operation, Maintenance
Pos : 11 /T echnisc he Dokumentation/ Betriebsanl eitungen/M ontag e, Betrieb, Wart ung/M ontag e/09500/T ec hni sche D at en Sprühkopf @ 4\ mod_1551775050996_20. doc x @ 34601 @ @ 1
Spray balls (static) are used for tank cleaning in the low-pressure range. Tank design and
possible tank internals determine the choice and the position of the spray ball. In
addition, the type and the level of contamination have to be taken into account.
The spray ball distributes the cleaning medium on the inside upper tank wall (see spray
circle Ø).
The tank wall is cleaned by the cleaning liquid flowing down from the tank top.
To guarantee a constant flow, the spray ball must have a minimum flow capacity. With
regard to one meter circumference of the tank and depending on the contamination level,
this capacity is approx. 25-35 l/min.
This results in the required quantity of cleaning media respectively the flow capacity of the
spray ball.
Spray balls are normally used with a cleaning-air-valve combination .