5
4 Operation
4.1 Layout of Front and Rear Panel
1
Output Current Adjust
Set cutting power from 20
– 60 amps
2
Power Pilot Lamp
This will light if the machine is connected to power
3
Alarm Pilot Lamp
When lit, this light indicates that over-temp limit has activated
4
Air Indicator
The AIR light will turn on if there is insufficient air pressure (Below 50 Psi)
5
Ready (DC Indicator)
Indicator is ON when DC output is active (trigger is depressed)
6
RUN/SET
Power ON in RUN, Change to SET for 10-sec air purge & Change to RUN to cut.
7
Cutting Gun Connector
Attach plasma cutting torch to flange. Secure tight.
8
Earth Cable Connector
Connects earth clamp cable to machine
9
Air Regulator/Dryer
Connect Compressor airline. Set to 70 psi.
10
Power Cord
Connect power cord to LINE power source.
11
Power Switch
Turns power ON/OFF to machine LINE power.