the screen. After a few seconds the endoscope will begin to take images in the window. 

If the picture comes from your PC camera or any other device, 

please click on „Device‟ 

on the top line of the image window and open the pull down menu. Choose the proper 

USB camera and close the pull down menu.

 

C

lick  on  „OPTIONS‟  and  click  on  „VIDEO  CAPTURE  PIN‟.  Choose  one  of  image 

window size in the drop-

down menu and click on „OK‟ to confirm.

 

 

TAKE PHOTOS

 

Click on 

„option‟ on the top of image window. Then click on „high resolution‟ in the 

drop-down menu to make sure there is a tick mark here. Close the drop-down menu. 

Push  down  the  button  that  is  located  on 

the  USB  cable  to  freeze  an  image.  Or  click 

„snap‟  on  the  top  of  image  window  to  take  a 

photo. 

The photo you have taken will be saved in 

the  computer  and  display  an  icon  on  the 

screen.   

If  your  system  could  not  freeze  an  image 

please follow steps to make it work: 

1,  click  on  „file‟  that  is  on  the  top  of  image 

window. 

2, click on the „set photo folder‟ 

3, designate the folder you want to save the photos 

4, click OK to confirm 

 

MORE WAYS TAKING PHOTOS 

Click on 

„option‟ on the top of image window. 

Then tick off 

„high resolution‟ in the drop-down menu. 

Close the drop-down menu. 

Now you get below functions: 

IMAGE FREEZ

 

Rap the space bar for freezing an image. 

If  you  want  to  save this  image  you  can  rap  the  return  key for  saving  the  image as a 

photo. 

Summary of Contents for eheV2-USB-S

Page 1: ...ronic product for the micro observations It is a tubular imaging system consisting of an optical lens an image sensor an illumination mechanism and an image transfer control circuit connected to a computer You can display the images captured by the Endoscope Microscope on the computer screen store them on the computer print them or send them over the Internet ...

Page 2: ...r reading SYSTEM REQUIREMENTS Windows 7 Vista XP TECHNICAL SPECIFICATIONS 1 DSP High Quality Digital Image Monarch Processor 2 Sensor high quality CMOS sensor 3 Resolution 1600X1200 4 Interface USB2 0 5 Frame rate 30 frames sec CIF and VGA 6 Focal distance 5mm infinity 7 Magnification 1x 200x 8 Diameter 8 2mm 9 Length 110mm 10 Timing snap 10 seconds 11 Image freeze just rap the space bar ...

Page 3: ...and then slightly screw down the knob Take the CD out of the box and place it into the CD ROM Find the icon of ehe exe and copy the ehe exe to your PC Plug the endoscope into the USB port and double click on the icon of ehe exe to open the image window DIRECTIONS FOR USE Rotate the dial on the USB cable to control the brightness of the LED on the USB endoscope After a short while you should see th...

Page 4: ...drop down menu Push down the button that is located on the USB cable to freeze an image Or click snap on the top of image window to take a photo The photo you have taken will be saved in the computer and display an icon on the screen If your system could not freeze an image please follow steps to make it work 1 click on file that is on the top of image window 2 click on the set photo folder 3 desi...

Page 5: ...taking a video 1 click on video capture 2 click on Set Time Limit and input how many seconds the video you want to take and tick the use time limit 3 click on the capture again 4 click on start capture 5 click on OK to start a record The video will be taken and stopped automatically when time is out The video is an AVI format User may move the AVI file to any folder FOCUSING Turn the knob of the e...

Page 6: ...stance levels SF can be used for the inspection of electronic parts machine parts skin hair and so on REFLECTOR TUBE Reflector tube is used for side view of any tubing inspection Take the reflector tube out of the peel pouch and put it on the endoscope like the photo shows Push the reflector tube to the end all the way and turn a little bit to confirm it is well fixed Please pay attention to this ...

Page 7: ...oscope user can look into ear and check the eardrum User needs to clean the ear canal with a cotton swab before checking the ear The ear wax would smear the lens and cause the image fuzzy While looking at the ear drum user should move the endoscope in the ear slightly back and forth to get the best focused image Before and after using the endoscope user should clean the head of endoscope by using ...

Reviews: