![background image](http://html1.mh-extra.com/html/hand-held-products/quick-check-qcolv-sv100/quick-check-qcolv-sv100_specifications_589721002.webp)
W orldw ide O ffices
O ffices S erving N orth Am erica
Skaneateles F alls, N Y
T el: +1 315 685 8945
or, in N orth Am erica:
+1 800 582 4263
napresales@ handheld.com
C harlotte, N C
T el: +1 704 998 3998
or, in N orth Am erica:
+1 800 582 4263
napresales@ handheld.com
O ffices S erving E urope,
M iddle E ast, and Africa
Europe
T el: +31 (0) 40 29 01 600
eupresales@ handheld.com
U nited Kingdom
T el: +44 (0) 1 925 240055
eupresales@ handheld.com
Italy
T el: +39 (0) 2 67 100752
eupresales@ handheld.com
F rance
T el: +33 (0) 1 41 158220
eupresales@ handheld.com
G erm any
T el: +49 (0) 7 477 151377
eupresales@ handheld.com
Spain
T el: +34 93 228 78 68
eupresales@ handheld.com
O ffices S erving Asia and the
P acific R im
H ong Kong
T el: +852 2511 3050
appresales@ handheld.com
Japan
T el: +813 5770 6312
appresales@ handheld.com
O ffices S erving Latin Am erica
N aples, F lorida
T el: +1 239 263 7600
lapresales@ handheld.com
São Paulo
T el: +55 11 5016 3454
lapresales@ handheld.com
R io D e Janeiro
T el: +55 21 2176 0250
lapresales@ handheld.com
W eb Site Address w w w .handheld.com
H and H eld Products, Inc., ("H and H eld Products”)
©
1999-2004. All rights reserved. Printed in the U .S.A.
D ue to H and H eld Products’ continuing product im provem ent program s, specifications and features herein are subject to change w ithout notice.
QCOLVSV-SS Rev B
12/04
Quick Check
®
On-Line SV Series Verifiers
Specifications
Dimensions
Height:
5.2 in. (13.2 cm)
Width:
4.4 in. (11.2 cm)
Depth:
2.4 in. (6.1 cm)
Mechanical/Electrical
Communication Port:
DB-9, male, RS-232C, programmable baud rate up to 115,200 baud
I/O Power:
DB-15, male, 5 programmable outputs, 2 sync 5VDC @ 1 amp required
Mounting:
2 sets of mounting holes on 2 surfaces, or clamp for tightening to 3/8 in. (.5 mm) rod
LEDs:
5
Environmental
Operating Temperature:
40 to 105° F (4 to 41° C)
Storage Temperature:
-4 to 140° F (-20 to 60°C)
Relative Humidity:
10 to 95% Non-condensing
Ambient Light:
Not to exceed .5 mW/sq-mm 600 nm to 700 nm (calculated at about 2% of laser light level; estimate, not verified)
MTBF:
10,000 hours (est.) (dominated by motor, then laser life)
Scanner
Scan Rate:
400 scans/second
Laser Power:
3 mW (+.5 mW)
Wavelength:
650-670 nm
Beam Shape:
Elliptical
Analysis Rate:
100 analyses/second (min.)
Bar Code Density
X Dimension:
6.6 mil (.2 mm) min. to 40 mil (1 mm) max.
Scan Width:
6 inches (15.2 cm)
X Dimension: 10 mil (.25 mm) or larger; 4.5 in. (11.4 cm) - (x dimension <10 mil)
Depth of Field:
±.125 in. (3.2 mm) min. with all verification analysis enabled
Symbologies
EAN/UPC with addenda, Code 39, Interleaved 2 of 5, Codabar, Code 128, Code 93
Operation Modes
Sync Mode
Moving Bar Codes:
A sync signal is used to indicate when an object or label containing a bar code has entered or exited the laser beam. Bar codes are
analyzed, ports activated, and transmissions sent as the bar codes pass through the beam. The QCOLV-SV100 is programmed for the
number of bar codes to expect during a sync period. Therefore, the QCOLV-SV100 detects missing or undetectable bar codes. A hardware
input is the most common sync source for Sync Mode.
Sync Mode
Stationary Bar Codes:
Bar codes are placed in the beam and held in a known position. A sync input commands the unit to turn on the laser beam, perform a
programmable number of scans, report the analysis, and turn off the laser beam. RS-232 communication sync command (-SA) is the most
common sync source. A rastering laser option is often used to analyze the bar code area.
Non Sync Mode
Free Scan Operation:
A sync signal is not used and the unit scans and analyzes bar codes as they pass through the laser beam. This mode is only recommended
if the QCOLV-SV100 is used as a bar code decoder, since it can’t report missing or undetectable bar codes.
Parameters Analyzed
Safety/Regulatory
FCC Class B, CE Certified
Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries.
Average Bar Deviation (Traditional method parameter)
Minimum Bar Deviation (Traditional method parameter)
Maximum Bar Deviation (Traditional method parameter)
PCS (Traditional method parameter)
Reflectance – Light (Traditional method parameter)
Reflectance – Dark (Traditional method parameter)
Ratio (Traditional method parameter)
Quiet Zone (Traditional method parameter)
X Dimension (Traditional method parameter)
Decodability (ANSI method parameter)
Defects (ANSI method parameter)
Edge Contrast (ANSI method parameter)
Global Threshold (ANSI method parameter)
Modulation (ANSI method parameter)
Overall Symbol Grade (ANSI method parameter)
Reference Decode (ANSI method parameter)
Rmin/Rmax (ANSI method parameter)
Symbol Contrast (ANSI method parameter)
Bar Code Direction (scanner decoder function)
Encoded Data (scanner decoder function)
Symbology Type (scanner decoder function)
% Decode (multiple scanning parameter)
Modulo Check Digits (mandatory symbology and optional
application parameters)