background image

W orldw ide O ffices 

O ffices S erving N orth Am erica 
Skaneateles F alls, N Y 

T el:  +1 315 685 8945  

or, in N orth Am erica:

  +1 800 582 4263 

napresales@ handheld.com 

C harlotte, N C  

T el:  +1 704 998 3998 

or, in N orth Am erica:

  +1 800 582 4263 

napresales@ handheld.com 

O ffices S erving E urope, 
M iddle E ast, and Africa 
Europe 

T el:  +31 (0) 40 29 01 600 
eupresales@ handheld.com  

U nited Kingdom  

T el:  +44 (0) 1 925 240055 
eupresales@ handheld.com  

Italy 

T el:  +39 (0) 2 67 100752 
eupresales@ handheld.com 

F rance 

T el:  +33 (0) 1 41 158220 
eupresales@ handheld.com  

G erm any 

T el:  +49 (0) 7 477 151377 
eupresales@ handheld.com  

Spain 

T el:  +34 93 228 78 68 
eupresales@ handheld.com  

O ffices S erving Asia and the 
P acific R im  
H ong Kong 

T el:  +852 2511 3050 
appresales@ handheld.com 

Japan  

T el:  +813 5770 6312 
appresales@ handheld.com 

O ffices S erving Latin Am erica 
N aples, F lorida 

T el:  +1 239 263 7600 
lapresales@ handheld.com 

São Paulo 

T el:  +55 11 5016 3454 
lapresales@ handheld.com 

R io D e Janeiro 

T el:  +55 21 2176 0250 
lapresales@ handheld.com

W eb  Site  Address  w w w .handheld.com  
H and H eld Products, Inc., ("H and H eld Products”)

 

©

1999-2004. All rights reserved.  Printed in the U .S.A.  

D ue to H and H eld Products’ continuing product im provem ent program s, specifications and features herein are subject to change w ithout notice. 

QCOLVSV-SS Rev B

12/04

Quick Check

®

 On-Line SV Series Verifiers 

Specifications

Dimensions

Height:

5.2 in. (13.2 cm)

Width:

4.4 in. (11.2 cm)

Depth:

2.4 in. (6.1 cm)

Mechanical/Electrical

Communication Port:

DB-9, male, RS-232C, programmable baud rate up to 115,200 baud

I/O Power:

DB-15, male, 5 programmable outputs, 2 sync 5VDC @ 1 amp required

Mounting:

2 sets of mounting holes on 2 surfaces, or clamp for tightening to 3/8 in. (.5 mm) rod

LEDs:

5

Environmental

Operating Temperature:

40 to 105° F (4 to 41° C)

Storage Temperature:

-4 to 140° F (-20 to 60°C)

Relative Humidity:

10 to 95% Non-condensing

Ambient Light:

Not to exceed .5 mW/sq-mm 600 nm to 700 nm (calculated at about 2% of laser light level; estimate, not verified)

MTBF:

10,000 hours (est.) (dominated by motor, then laser life)

Scanner

Scan Rate:

400 scans/second

Laser Power:

3 mW (+.5 mW)

Wavelength:

650-670 nm

Beam Shape:

Elliptical

Analysis Rate:

100 analyses/second (min.)

Bar Code Density
X Dimension:

6.6 mil (.2 mm) min. to 40 mil (1 mm) max.

Scan Width:

6 inches (15.2 cm)
X Dimension:  10 mil (.25 mm) or larger; 4.5 in. (11.4 cm) - (x dimension <10 mil)

Depth of Field:

±.125 in. (3.2 mm) min. with all verification analysis enabled

Symbologies

EAN/UPC with addenda, Code 39, Interleaved 2 of 5, Codabar, Code 128, Code 93

Operation Modes

Sync Mode
Moving Bar Codes:

A sync signal is used to indicate when an object or label containing a bar code has entered or exited the laser beam.  Bar codes are
analyzed, ports activated, and transmissions sent as the bar codes pass through the beam.  The QCOLV-SV100 is programmed for the
number of bar codes to expect during a sync period.  Therefore, the QCOLV-SV100 detects missing or undetectable bar codes.  A hardware
input is the most common sync source for Sync Mode.

Sync Mode
Stationary Bar Codes:

Bar codes are placed in the beam and held in a known position.  A sync input commands the unit to turn on the laser beam, perform a
programmable number of scans, report the analysis, and turn off the laser beam.  RS-232 communication sync command (-SA) is the most
common sync source.  A rastering laser option is often used to analyze the bar code area.

Non Sync Mode
Free Scan Operation:

A sync signal is not used and the unit scans and analyzes bar codes as they pass through the laser beam.  This mode is only recommended
if the QCOLV-SV100 is used as a bar code decoder, since it can’t report missing or undetectable bar codes.

Parameters Analyzed

Safety/Regulatory

FCC Class B, CE Certified

Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries.

Average Bar Deviation (Traditional method parameter)
Minimum Bar Deviation (Traditional method parameter)
Maximum Bar Deviation (Traditional method parameter)
PCS (Traditional method parameter)
Reflectance – Light (Traditional method parameter)
Reflectance – Dark (Traditional method parameter)
Ratio (Traditional method parameter)
Quiet Zone (Traditional method parameter)
X Dimension (Traditional method parameter)
Decodability (ANSI method parameter)
Defects (ANSI method parameter)
Edge Contrast (ANSI method parameter)

  Global Threshold (ANSI method parameter)
  Modulation (ANSI method parameter)

Overall Symbol Grade (ANSI method parameter)
Reference Decode (ANSI method parameter)
Rmin/Rmax (ANSI method parameter)
Symbol Contrast (ANSI method parameter)
Bar Code Direction (scanner decoder function)
Encoded Data (scanner decoder function)
Symbology Type (scanner decoder function)
% Decode (multiple scanning parameter)
Modulo Check Digits (mandatory symbology and optional
application parameters)