HTS-AT10 Digital Timer
5
-4)
Weekly Cycle
:
Adjust the Select switch to No. 4
(Time Differene;10min~24Hrs)
HTS-AT10 Digital Timer
6.Wiring How to
③
Set
repeat ON Minute
with
①
Set
repeat ON day of week
with
“▲”,”▼” and press “Menu/Move” once.
.
②
Set
repeat ON Hour
with
“▲”,”▼” and press “Menu/Move” once
.
:
Adjust the Select switch to No. 4
(Time Differene;10min 24Hrs)
Change to setting mode by pressing “Menu/Move” once
.
1)Direct control of load
③
Set
repeat ON Minute
with
“▲”,”▼” and press “Menu/Move” once.
⑤
Set
repeat OFF Hour
with
“▲”,”▼” and press “Menu/Move” once.
④
Set
repeat OFF day of week
with
“▲”,”▼” and press “Menu/Move” once
.
⑥
Set
repeat OFF Minute
with
“▲”,”▼” and press “Menu/Move” once
.
2)Electromagnetic control
(Single Phase)
-8-
Initialize
,
and press Menu/Move once
.
⑦
Set
repeat ON Hour difference
with “▲”,”▼” and press “Menu/Move” once
.
⑧
Set
repeat OFF Hour difference
with “▲”,”▼” and press “Save” once
.
-9-
NO NC
COM POWER
HTS-AT10 Digital Timer
7.Product Specifications
MODEL
HTS-AT10
HTS-AT10 Digital Timer
8-1)Cautions
1)Input voltage must be within allowed voltage range and
the right capacity circuit breaker and wire must be used
Nominal Voltage
220VAC/60HZ
Load capacity
resistance load 10A(inductive load:2A)
Operation Mode
(no. of operations)
Weekly Timer(25),Weekly Pulse(24),
Yearly Timer(10), Weekly Cycle(10)
Operation Cycle
Weekly or Yearly
Installation
Exposed on the panel, DIN Rail used
the right capacity circuit breaker and wire must be used.
2)Connect a
Surge Absorber
after using electromagnetic
switch to prevent malfunction an damage when use other
than resistance load
3)Keep out of reach of children to prevent electric shocks.
4)Bodily damage or property damage caused by misuse or
negligence cannot be held responsible to the
manufacturer.
Operation Temperature -10℃ ~ 60℃
Humidity Range
0% ~ 80%
Output type
RELAY contact type(1C)
Dimensions
52(W)x96(L)x48(H)mm
8
-2)Warranty
1) Any faulty that occurred in the manufacturing process or
while in proper operation within
18 months of the
manufactured date
, we will repair free of charge if
contacted to our company.
2)Repairs that fall into below categories are charged for
repair services even within the warranty period.
①Malfunctions caused by User imputation.
②M lf
ti
d b U
i
ti
www.hsa2000.co.kr
-10-
②Malfunctions caused by User incautiousness
③Malfunctions caused by natural disasters
④Repairs performed by unauthorized personnel
other than an employee of our company who
modified or damaged the product
-11-
●Main Office & Factory :
293-3, HYOMOK 2 DONG,
DONG GU, DAEGU, SOUTH KOREA
TEL . +82-53-745-4720
FAX. +82-53-745-4726