![Hamron 007982 Operating Instructions Manual Download Page 27](http://html1.mh-extra.com/html/hamron/007982/007982_operating-instructions-manual_3491116027.webp)
EN
27
NOTE:
Voltage for 12 V system at 25°C, multiply by 2 for 24 V system.
BATTERY VOLTAGE LIMITS AND CHARGING TIMES
BATTERY TYPE
SEALED
GEL
WET CELL
Overvoltage, disconnection
16.0 V
16.0 V
16.0 V
Charging voltage, charging stopped
15.0 V
15.0 V
15.0 V
Overvoltage, reconnection
15.0 V
15.0 V
15.0 V
Charging voltage, equalisation charging
14.6 V
——
14.8 V
Charging voltage, boost charging
14.4 V
14.2 V
14.6 V
Charging voltage, float charging
13.8 V
13.8 V
13.8 V
Charging voltage, return to boost charging 13.2 V
13.2 V
13.2 V
Undervoltage, reconnection
12.6 V
12.6 V
12.6 V
Undervoltage warning stops
12.2 V
12.2 V
12.2 V
Undervoltage warning
12.0 V
12.0 V
12.0 V
Undervoltage, disconnection
11.1 V
11.1 V
11.1 V
Undervoltage, over-discharge limit
10.6 V
10.6 V
10.6 V
Equalisation charging time
120 min
——
120 min
Boost charging time
120 min
120 min
120 min
MAINTENANCE
Clean the surface of the solar panel at regular intervals with a soft cloth.