Care and Maintenance
STORAGE
□ Between uses or during periods of extended inactivity:
Turn control knob to the "OFF" position.
Disconnect the LP cylinder and move to a secure, well-ventilated location outdoors.
Store the heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail,
snow, dust and debris).
NOTE:
Never leave LP gas tank exposed to direct
sunlight or excessive heat.
If desired, use cover (s) to protect the heater and
help prevent buildup in air passages.
CAUTION:
THD Wait until heater is cool before covering.
Troubleshooting
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The burner does
not light.
1. The gas pressure is low.
2. The orifice is blocked.
3. The control knob is not in the “ON”
position.
1. Turn the gas cylinder valve “OFF” and
replace the cylinder.
2. Clear the blockage.
3. Turn the control knob to the "ON" position.
The burner flame
is low.
1. The gas pressure is low.
2. The control knob is not positioned at
“High”.
3. The burner jet is partially blocked.
4. Outdoor temperature is less than 40°F and
tank is less than 1/4 full.
5. The supply hose is bent or kinked.
1. Turn the gas cylinder valve “OFF” and
replace the cylinder.
2. Position the control knob to the "HIGH"
position.
3. Clear blockage.
4. Use a full gas cylinder.
5. Straighten the hose.
There is carbon
build up.
Seasonal accumulation.
Wipe off before lighting.
There is thick
black smoke.
There is blockage in the burner.
Remove blockage and clean the burner inside
and outside.