background image

 

 

 

 

Item #186-051

USE AND CARE GUIDE

1-800-527-0998

HAMPTONBAY.COM 

MORESCO 32 INCH CEILING FAN

Model #14411

THANK YOU

THANK YOU

Questions, problems, missing parts? Before returning to the store,  

call Hampton Bay Customer Service 

8 a.m. - 6 p.m., EST, Monday-Friday 

Summary of Contents for MORESCO 14411

Page 1: ...RE GUIDE 1 800 527 0998 HAMPTONBAY COM MORESCO 32 INCH CEILING FAN Model 14411 THANK YOU THANK YOU Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday ...

Page 2: ...n Motor Assembly Making the Electrical Connections Installing the Wall Switch Finishing the Fan Motor Installation Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 8 9 10 11 12 13 Operation Wall Control Operating Instructions Reverse Switch Operating Instructions Care and Cleaning Troubleshooting Service Parts 14 14 15 15 16 17 Table of Contents ...

Page 3: ...e ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs Use only UL listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 ft clearance from the trailing edge of the blades to the ...

Page 4: ...rotected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty We hereby disclaim any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The dur...

Page 5: ...nd lock washers Wall plate screws 6 32 x 8mm screws Wall switch screws 6 32 x 22mm screws Plastic wire nut Mounting ring screws preassembled 5 32 in x 8mm screws Light kit plate screws preassembled 5 32 in x 8mm screws Part Part Description Description 10 3 1 4 2 2 4 3 3 Quantity Quantity 5 HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance NOTE Hardware shown to actual size unles...

Page 6: ... Glass shade Wall switch Wall plate 50W halogen bulb Pre Installation continued 6 Part Part A B C D E Quantity Quantity 1 1 1 3 1 Quantity Quantity 1 1 1 1 1 Description Description Mounting bracket Fan motor assembly Canopy ring preassembled Blades Light kit mounting plate A F G H I J C B D E ...

Page 7: ...ts bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show two different ways to mount the outlet box JJ not included WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the outlet box An outlet box ...

Page 8: ...of fire electric shock or other personal injury mount the fan only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box Lift the fan into position by hanging the fan motor assembly B onto the hook from the ceiling mounting bracket A allowing it to hang freely A WW JJ A B C 2 8 Attaching the mounting bracket to the electric...

Page 9: ...ot wire VV from the ceiling to the black white wire PP from the wall switch H If your outlet box JJ has a ground wire green or bare copper connect the wall switch s H ground wire SS to it otherwise connect the wall switch s H ground wire SS directly to one of the screws from the outlet box JJ WARNING Check to see that all connections are tight including ground and that no bare wire is visible at t...

Page 10: ...wall switch screws FF provided Attach the wall plate I over the wall switch H and secure with the two wall plate screws EE provided WARNING Hook up in series only Do not connect the hot and neutral wires of the electric circuit to the transmitter wall switch damage to the switch and possible fire could occur WARNING Remember to shut the power off at the circuit breaker or fuse box ...

Page 11: ...ook and engage the key holes with the two mounting bracket screws DD previously loosened 6 Attaching the fan motor assembly to the mounting bracket Install the two mounting bracket screws DD previously removed and tighten all four mounting bracket screws DD Raise up canopy ring C and line up the four tabs with the four grooves on the canopy Once lined up slide the canopy ring C and secure it to th...

Page 12: ...talling balancing the blades D or cleaning the fan Do no insert foreign objects between rotating fan blades D AA B D JJ Insert a blade D through the slots in the bottom band Align the holes from the blade D to the holes from the motor and secure the blade in place with screws and fiber washers AA provided Repeat this process to attach the other three blades D 12 ...

Page 13: ...narrow section of the key holes Secure the light kit mounting plate E by tightening the two mounting ring screws HH previously loosened and the one previously removed Attaching the light kit plate to the light kit mounting plate While holding the light kit plate F under your fan B make the polarized plug connections White to white Black to black Install the light kit plate F onto the light kit mou...

Page 14: ...power by turning off the circuit breaker or removing the fuse at the fuse box Turning power off using the fan switch is not sufficient to prevent electric shock G J F B E Operation WALL CONTROL OPERATING INSTRUCTIONS WALL CONTROL OPERATING INSTRUCTIONS Restore power to the ceiling fan and test for proper operation buttons The fan 4 speed control is used to set the fan speed as follows Turns the fa...

Page 15: ...possibly cause an electrical shock Do not apply oil to your fan or motor The motor has permanently lubricated sealed ball bearings Do not Do not NOTE Wait for the fan to stop before reversing the direction of the blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing This switch controls directio...

Page 16: ...the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box Do not connect the fan with wall mounted variable speed control s Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling abov...

Page 17: ...ion Blade attachment hardware 3 16 in x 12 3mm screws and fiber washers Plastic wire nut Balance kit Mounting bracket screws 3 16 in x 1 2 in screws and lock washers Wall plate screws 6 32 x 8mm screws Wall switch screws 6 32 x 22mm screws Plastic wire nut Mounting ring screws 5 32 in x 8mm screws Light kit plate screws 5 32 in x 8mm screws A F AA BB CC DD EE FF GG HH II G H I J D E B C Service Pa...

Page 18: ...estions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 800 527 0998 HAMPTONBAY COM Retain this manual for future use RM231B000001 C ...

Reviews: