Hampton® H35U Direct Vent Freestanding Gas Stove
installation
Locating Your Gas Stove
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility for
servicing and proper operation.
Manufactured Mobile Home
Additional Requirements
1)
Ensure that structural members are not cut or
weakened during installation.
2)
Ensure proper grounding using the #8 ground
lug provided.
3)
Appliance must be anchored to the floor with
the supplied anchoring methods.
Combustion and Ventilation Air
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside the
room is not required.
A) Cross Corner
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/Alcove
For Vent Termination requirements, see the "Exterior
Vent Terminal Locations" section.
Be sure to check the vent termination clearance
requirements from decks, windows, soffits, gas
regulators, air supply inlets and public walkways as
specified in the "Exterior Vent Terminal Locations"
section and in your local building codes.
The gas appliance and vent system must be
vented directly to the outside of the building and
never attached to a chimney serving a separate
solid fuel or gas-burning appliance.
Each direct
vent gas appliance must use it's own separate vent
system. Common vent systems are prohibited.
Safety Precautions for The
Installer
1)
Wear gloves and safety glasses for protection.
2)
Exercise extreme caution when using ladders
or on roof tops.
3)
Be aware of electrical wiring locations in walls
and ceilings.
Venting Introduction
The Horizontal Termination Kit and the rigid pipe
venting systems, in combination with the Direct
Vent Freestanding Gas Stoves H35 have been
tested and listed as direct vent heater systems by
Warnock Hersey.
These units use the "balanced flue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer pipe
draws outside combustion air into the combustion
chamber thereby eliminating the need to use heated
room air for combustion and losing warm room air
up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented
directly to the outside of the building, and never
be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the
installation. Failure to follow these instructions may
create a fire or other safety hazard, and will void the
warranty. Be sure to check the venting and clear-
ance to combustible requirements. Consult your
local building codes before beginning installation.
The location of the termination cap must conform
to the requirements in the "Exterior Vent Terminal
Locations" section.
Installation Precautions
These venting systems are engineered products
that have been designed and tested for use with
the H35. The warranty will be voided and serious
fire, health or other safety hazards may result from
any of the following actions:
1)
Installation of any damaged Direct Vent com-
ponent
2)
Unauthorized modification of the Direct Vent
System
3)
Installation of any component part not
approved by FPI - Fireplace Products
International Ltd.
4)
Installation other than as instructed by the
approved rigid pipe manufacturers and FPI
Fireplace Products International Ltd.
Warning: Always maintain required clear-
ances (air spaces) to nearby combustibles
to prevent a fire hazard. Do not fill air
spaces with insulation.
Vent Restrictor Position
Vent restriction is required for certain venting instal-
lations, see the diagrams in "Venting Arrangement"
section to determine if they are required for your
installation.
To set the Vent restriction as indicated in the dia-
grams in the "Venting Arrangement" section, simply
loosen the screws and push the vent restrictor plate
to the correct position. Tighten the screws.
Horizontal Termination:
Vent Restrictor setting
Vertical Termination:
Vent Restrictor setting
Summary of Contents for H35U-NG
Page 51: ...Hampton H35U Direct Vent Freestanding Gas Stove 51 notes ...
Page 56: ...56 Hampton H35U Direct Vent Freestanding Gas Stove warranty ...
Page 57: ...Hampton H35U Direct Vent Freestanding Gas Stove 57 notes ...
Page 58: ...58 Hampton H35U Direct Vent Freestanding Gas Stove notes ...
Page 59: ......