WARRANTY

Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit 
thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original purchaser of 
a Hampton Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

External casting, not directly in contact with the fi re, such as hobs, sides, ash lips, legs, fronts and fi re doors, are covered against cracks and warps resulting from manufacturer 
defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

The combustion chamber, heat exchanger, burner tubes/pans and logs are covered under the Limited Lifetime Warranty for fi ve (5) years for parts and subsidized labour* 
and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly 
components, and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are 
considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from 
date of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components are covered by Simpson Dura-Vent Inc. warranty.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any 
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days 
of installation. Reported damage after this time will be subject to rejection.

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent 
provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated 
for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Hampton product. FPI will not be liable for results or costs of workmanship from 
unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint (charcoal units),  porcelain (including pinholes, scratches and minor shade mismatch), door or glass 
gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufac-
tured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Embers, door and glass, gaskets, door handles, paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence 
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical 
systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your war-
ranty on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Summary of Contents for H15-LP1

Page 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Page 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H15 1 has been approved by Warnock Hersey for both safety...

Page 3: ...ale 6 Before You Start 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove 8 Manufactured Mobile Home Additional Requirements 8 Combustion and...

Page 4: ...he correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exible connecto...

Page 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 6: ...hetypeofgasindicatedontherating plate This appliance is not convert ible for use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI FIEDSERVICEPERSON THI...

Page 7: ...equire ments See Venting Introduction to Dura Vent Vertical Termination sections 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Pilot Adjustmen...

Page 8: ...ATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 Fan Speed Control 1 Grommet 1 Remove the rear access panel on the back of the sto...

Page 9: ...ged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 12 Sl...

Page 10: ...fcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the ch...

Page 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Page 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Page 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Page 14: ...t Temp Ameri Vent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNI...

Page 15: ...8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertic...

Page 16: ...etween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 fee...

Page 17: ...talled in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with hori zont...

Page 18: ...lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the exible liner will accommodate However keep the...

Page 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Page 20: ...ering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex liner to the desi...

Page 21: ...Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 380 946 Horizontal Termination Kit which includes 1 6...

Page 22: ...ter wall of the vent pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements fromdecks windows sof ts gasregulators air supply inlets and publi...

Page 23: ...of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards the termination...

Page 24: ...e For best results and optimum per formancewitheachapprovedventing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in draf...

Page 25: ...rformance issues notcoveredunderwarranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportB...

Page 26: ...ecured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure...

Page 27: ...Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the support in the opening Lower it to the correct height as determined by the tab...

Page 28: ...ter turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do not over tighten Valve Description 1 Gas on off knob 2 Manual...

Page 29: ...elcro Hook Black 904 782 Velcro Hook Black 1 Shut off the gas supply 2 Lift off Cast Top remove Cast Front and Glass Door refer to the glass replace ment section in the manual and carefully remove log...

Page 30: ...nel Before After 12 Pull off the pilot cap to expose the pilot ori ce 13 Unscrew the pilot ori ce with the allen key and replace with the LP pilot ori ce in the kit 14 Remove burner ori ce with a 1 2...

Page 31: ...wire to the DC Sparker Piezo Ignitor 31 Attach the heat shield to the DC sparker then mount onto the stove using the velcro already attached to the DC Sparker mounting bracket Note We recommend attac...

Page 32: ...r Front Log e Embers 902 156 f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log A B 4 Remove Glass Door 5 Carefully remove the logs from the unit and unwrap them Th...

Page 33: ...any ame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top D A A B C D 8 Take the embers and place on the burner in the space between the...

Page 34: ...ed non anticipator type thermostat that is CSA ULC or UL approved may be used 14 GA 16 GA 18 GA 20 GA 22 GA 50 Ft 32 Ft 20 Ft 12 Ft 9 Ft Recommended Maximum Lead Length Two Wire When Using Wall Thermo...

Page 35: ...failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do no...

Page 36: ...ton H15 1 Direct Vent Freestanding Gas Stove INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this...

Page 37: ...ew res a white lm may develop on the glass front as part of the curing process The glass should be cleaned or the lm will bake on and become very dif cult to remove Use a non abrasive cleaner and NEVE...

Page 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Page 39: ...Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process SHOULD BE ALERTE...

Page 40: ...rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully rem...

Page 41: ...the burner tray assembly simply reverse these instructions To remove valve from valve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pil...

Page 42: ...023 Fan De ector Left 17 910 142 Thermodisc Switch 20 380 012 Rear Panel 25 910 330 Fan Speed Control 120V 26 904 569 Knob Fan Speed Control 28 910 241 Burner ON OFF Switch 29 260 037 Rear Control Pan...

Page 43: ...Nut 64 908 672 Control Panel Decal 65 490 061 Switch Plate 936 170 Ori ce Gasket 66 910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 380 013 Pilot Holder 68 W840470 Pilot Assembl...

Page 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Page 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Reviews: