If your ceiling fan does not have an existing UL Listed mounting 
box, then install one using the following instructions:

Disconnect the power by removing the fuses or turning off  
the circuit breakers.

Secure the outlet box (not included) directly to the building 
structure. Use appropriate fasteners and materials (not 
included). The outlet box and its bracing must be able to fully 
support the weight of the moving fan (at least 35 lb). Do not 
use a plastic outlet box.

The illustrations below show three different ways to mount the 
outlet box (not included).

To hang your fan where there is an existing fixture but no ceiling 
joist, you may need an installation hanger bar (not included) as 
shown above.

Outlet Box

Outlet Box

Hanger Bar

Outlet Box

Recessed

Outlet

Box

Ceiling

Mounting

Bracket

 

WARNING:

 

To reduce the risk of fire, electric shock, or 

personal injury, mount the fan to an outlet box marked 
acceptable for fan support using the screws provided with the 
outlet box. An outlet box commonly used for the support of 
lighting fixtures may not be acceptable for fan support and 
may need to be replaced. If in doubt, consult a qualified 
electrician.

NOTE:

 

You may need a longer downrod to maintain proper 

blade clearance when installing on a steep, sloped ceiling. 
The maximum angle allowable is 18° away from horizontal. If 
the canopy (B) touches the hanger ball/downrod assembly 
(D), remove the decorative canopy bottom cover (C) and turn 
the canopy (B) 180° before attaching the canopy (B) to the 
mounting bracket (A).

MOUNTING OPTIONS

Installation

Summary of Contents for GLENDALE III AK338-MBK

Page 1: ...me improvement needs Thank you for choosing Hampton Bay 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Sat...

Page 2: ...liced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of t...

Page 3: ...stallation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corr...

Page 4: ...t shown to actual size AA BB CC DD Plastic wire nut Blade attachment screw and fiber washer 9 Watt LED bulb Pull chain and fob Part Description 3 16 3 2 Quantity HARDWARE INCLUDED Pre Installation con...

Page 5: ...ription Blade Blade arm Light kit Glass shade Quantity 5 5 1 3 Part A B C D E Quantity 1 1 1 1 1 Description Mounting bracket preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod a...

Page 6: ...ar not included as shown above Outlet Box Outlet Box Hanger Bar Outlet Box Recessed Outlet Box Ceiling Mounting Bracket WARNING To reduce the risk of fire electric shock or personal injury mount the f...

Page 7: ...s in the collar on top of the fan motor assembly E Carefully insert the clevis pin GG through the holes in the collar and the hanger ball downrod assembly D Be careful not to jam the clevis pin GG aga...

Page 8: ...motor assembly E collar Remove three of the six collar mounting screws with lock washers II every other one from the collar on top of the fan motor assembly E II II WARNING Failure to completely tigh...

Page 9: ...t A is toward the outlet box Securely tighten the two mounting screws 5b 5a Hanging instructions for standard mounting Hanging instructions for close to ceiling mounting WARNING The tab in the ring mu...

Page 10: ...plastic wire nuts AA with your fan Secure the plastic wire nuts AA with electrical tape Make sure there are no loose strands or connections Make wire connections as follows using the wire nuts AA Fro...

Page 11: ...es Green or Bare Wire Ground On a dual switch the fan and light can be turned on or off separately Make wire connections as follows using the wire nuts AA Wall switch not included From Fan To Outlet B...

Page 12: ...EE are engaged and firmly tightened WARNING The locking slots of the canopy B are provided only as an aid to mounting Do not leave the fan assembly unattended until all four canopy mounting screws wi...

Page 13: ...o remaining screws and fiber washers BB Tighten each screw securely starting with the center screw Make sure the blade F is straight Repeat these steps for the remaining blades 10 Fastening the blade...

Page 14: ...ght kit mounting screws NN provided Be sure to tighten all screws Install the glass shade I into the glass holder by aligning the slot OO on the glass shade I with the tab PP in the glass holder and t...

Page 15: ...gs for warm or cool weather depend on factors such as the room size ceiling height and numbers of fans The light pull chain controls the light kit ON and OFF Operation PULL CHAIN OPERATING INSTRUCTION...

Page 16: ...hour breaking in period Most noises associated with a new fan disappear during this time If using the ceiling light kit make sure the glassware is secured tightly Make sure there is a short distance...

Page 17: ...pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Reviews: