Safety Rules - Read and Save These Instructions

To reduce the risk of electric shock, insure electricity has been turned off 
at the circuit breaker or fuse box before beginning.

All wiring must be in accordance with the National Electrical Code 
“ANSI/NFPA 70-1999” and local electrical codes. Electrical installation 
should be performed by a qualified licensed electrician.

WARNING:

 To reduce the risk of electrical shock or fire, do not use this 

fan with any solid-state fan speed control device. It will permanently 
damage the electronic circuitry.

CAUTION:

 To reduce the risk of personal injury, use only the screws

provided with the outlet box.

The outlet box and support structure must be securely mounted and 
capable of reliably supporting a minimum of 35 pounds, Use only UL 
Listed outlet boxes marked 

“FOR FAN SUPPORT”

.

The fan must be mounted with a minimum of 7 feet clearance from the 
trailing edge of the blades to the floor.

Avoid placing objects in the path of the blades.

To avoid personal injury or damage to the fan and other items, be 
cautious when working around or cleaning the fan.

Do not use water or detergents when cleaning the fan or fan blades. A dry 
dust cloth or lightly dampened cloth will be suitable for most cleaning.

After making electrical connections, spliced conductors should be turned 
upward and pushed carefully up into outlet box. The wires should be 
spread apart with the grounded conductor and the equipment-grounding 
conductor on one side of the outlet box and ungrounded conductor on the 
other side of the outlet box.

All set screws must be checked and retightened where necessary before 
installation.

1

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

WARNING

TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE 

BLADE ARMS (ALSO REFERRED TO AS FLANGES), WHEN 

INSTALLING THE BRACKETS, BALANCING THE BLADES OR 

CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS IN– 

BETWEEN ROTATING FAN BLADES.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE 

FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE 

OUTLET BOX.

ATTENTION

FAN INCLUDES A 190W LIMITER TO COMPLY WITH THE 

DEPARTMENT OF ENERGY 2009 REGULATION.  LAMPING THIS 

PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT.  

PLEASE USE BULBS WITH A TOTAL WATTAGE UNDER THE 190W 

REGULATION.

Summary of Contents for Devereaux II

Page 1: ...Devereaux II 52 in Ceiling Fan Owner s Manual Devereaux II Ventilador de Techo de 1 32 m Manual del Propietario 321 977 ...

Page 2: ...Devereaux II by Hampton Bay ...

Page 3: ...ceiling fan This product has been manufactured with the highest standards of safety and quality Table of Contents Safety Rules 1 Unpacking Your Fan 2 Installing Your Fan 3 Installing the Light Kit 10 Operating Your Transmitter 11 Care of Your Fan 13 Troubleshooting 13 Specifications 14 Warranty Information 15 321 977 792145355960 219032 ...

Page 4: ...tious when working around or cleaning the fan Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding c...

Page 5: ...lade arms 5 1 2 3 4 5 6 Mounting plate Light kit assembly Glass shade Glass frame 40 Watt E12 candelabra bulbs 3 Receiver with 6 wire nuts Transmitter holder 2 mounting screws 12V MN21 A23 battery 7 8 9 10 11 12 13 14 Blade Attachment Hardware 16 Screws with Fiber Washers Electrical Hardware 3 Plastic Wire Nuts Balance Kit A B C WARNING DO NOT INSTALL OR USE FAN IF ANY PART IS DAMAGED OR MISSING C...

Page 6: ...G SCREWS PROVIDED WITH THE OULET BOX OUTLET BOX COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURE MAY NOT BE ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT Outlet Box Outlet Box Outlet Box Figure 2 Figure 1 Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable i...

Page 7: ... the hanger ball lower the hanger ball and remove the pin remove all 3 pieces from the downrod and assemble them onto the new longer downrod before proceeding step 4 The longer downrod is available at any Home Depot store Route wires exiting from the top of the fan motor through the coupling cover canopy cover canopy and then through the ball downrod Figure 6 1 2 3 4 Align the holes at the bottom ...

Page 8: ...ires through the center hole in the ceiling mounting bracket as shown in Figure 7 Install the ceiling mounting bracket on the outlet box with the screws and washers provided with your outlet box Figure 7 Security tighten the two mounting screws Carefully lift the fan assembly up to the ceiling mounting bracket and seat the hanger ball in the mounting bracket socket Make sure the tab on the mountin...

Page 9: ...ck the wire connections up into the outlet box 3 4 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling as Figure 10 1 If you feel you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician Follow the steps below to connect the fan to your household wiring Use the wire nuts supplied with your fan...

Page 10: ...cket turn canopy until it locks in place at the narrow section of the key holes Fig 12 Align the circular hole on canopy with the remaining hole on the mounting bracket secure by tightening the two set screws Note Adjust the canopy screws as necessary until the canopy and canopy cover are snug 1 2 3 Finishing the Fan Installation WARNING CHECK TO SEE THAT ALL CONNECTIONS ARE TIGHT INCLUDING GROUND...

Page 11: ...ng the Fan Blades Attach blades to blade arms using three screws with fiber washers Fig 13 Start a screw into the blade arm do not tighten Repeat for the 2 remaining screws and washers Tighten each screw securely starting with the center screw Make sure the blade is straight Repeat steps for the remaining blades Fasten the blade assemblies to the motor by lining up the slots of the blade arms with...

Page 12: ... Minutes Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable 1 2 3 The following procedure should correct most fan wobble Check after each step Figure 15 Touching Ceiling Figure 16 Attaching the Mounting Plate Remove 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove Place the key holes on the mounting plate over the 2 screws previously loosen...

Page 13: ...ounting plate turn light kit assembly until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Fig 17 Install 3 x 40W candelabra bulbs included Remove the decorative nut and plastic nut from the light kit stem Raise the glass shade up against the light kit assembly place the plastic nut over the light kit st...

Page 14: ...F Press and hold the button to set the desired brightness The light key has an autoresume it will stay at the same brightness as the last time it was turned off 1 2 3 Restore power to the ceiling fan and test for proper operation Operating Your Transmitter Figure 20 Installing the Battery Figure 19 Install 12V MN21 A23 battery included to prevent damage to transmitter remove the battery if not use...

Page 15: ...tioner on a higher setting without affecting your comfort Cool weather Clockwise direction An upward airflow moves warm air off the ceiling area Fig 23 This allows you to set your heating unit on a lower setting without affecting your comfort NOTE WAIT FOR FAN TO STOP BEFORE CHANGING THE SETTING OF THE SLIDE SWITCH Figure 22 Figure 23 Figure 21 Holder Screws Plugs Remove the two plugs from the hol...

Page 16: ...nections in the switch housing Check to make sure the dip switches from the transmitter and receiver are set to the same frequency Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub is tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period...

Page 17: ...TS AMPS WATTS RPM CFM N W G W C F 52 120 11 25 kgs 24 75 lbs 12 75 kgs 28 05 lbs 2 58 LOW MED HIGH 0 34 0 49 0 56 12 34 66 60 116 165 1748 3616 5420 These are approximate measures They do not include Amps and Wattage used by the light kit ...

Page 18: ... unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to Those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some...