HAMPTON BAY 91171 Installation And Operation Manual Download Page 3

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 13

Care and Cleaning ............................................................. 14

Troubleshooting ................................................................. 14

1. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70-1999 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

2. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only 
UL Listed outlet boxes marked “Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less.”

3. 

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

4. 

Do not operate the reversing switch while the fan blades are 
in motion. You must turn the fan off and stop the blades before 
you reverse the blade direction.

5. 

Do not place objects in the path of the blades.

6. 

Electrical diagrams are for reference only. Light kits that are 
not packed with the fan must be UL-listed and marked suitable 
for use with the model fan you are installing. Switches must be 
UL General Use Switches. Refer to the instructions packaged 
with the light kits and switches for proper assembly.

7. 

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box.

8. 

All set screws must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do not

insert objects in the path of the blades.

WARNING:

 To reduce the risk of fire, electric shock 

or personal injury, mount to outlet box marked 

“acceptable for fan support of 35lbs. (15.9 Kg) or 

less” and use screws provided with the outlet box.

WARNING:

 To reduce the risk of fire or electric

shock, do not use this fan with any solid-state speed

control device.

WARNING:

 Remove the rubber motor stops on

the bottom of the fan before installing the blades or

testing the motor.

WARNING:

 To avoid possible electrical shock,

turn the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

CAUTION:

 To avoid personal injury or damage to the fan 

and other items, use caution when working around or 

cleaning the fan.

Summary of Contents for 91171

Page 1: ...fan speeds to create an organic breeze effect Fan Light OFF ON Turns fan light off or on Select and slide to dim or brighten light Questions problems missing parts Before returning to the store call C...

Page 2: ...this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for...

Page 3: ...trical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding condu...

Page 4: ...shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particu...

Page 5: ...g pin 1 Part Description Quantity EE Extra plastic plug to be used for fan wothout light kit 1 FF Pull chain 2 GG Extra blade bracket screw and lockwasher 1 HH Close to ceiling mount hardware rubber g...

Page 6: ...ight kit fitter assembly 1 Part Description Quantity F Decorative motor collar cover 1 G Blade 5 H Blade bracket flange screws pre installed 5 I Glass bowl 1 J LED Light bulb 9 5 Watt maximum 3 IMPORT...

Page 7: ...Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations...

Page 8: ...he collar M on top of the motor housing D Remove the canopy ring KK from the canopy C by turning the ring counter clockwise until it unlocks Remove the mounting bracket A from the canopy C by loosenin...

Page 9: ...e fan motor housing D Route the wires exiting the top of the fan motor assembly D through the rubber gasket HH canopy ring KK and ceiling canopy C make sure the slot openings are on top place the rubb...

Page 10: ...taching wiring Failure to hang the fan properly by following these instructions may result in the hook breaking causing the fan to fall The hook must pass from inside to the outside of the canopy C C...

Page 11: ...The locking slots of the ceiling canopy are provided only as an aid to mounting Do not leave the fan assembly unattended until all four canopy screws are engaged and firmly tightened SS A C L Careful...

Page 12: ...ached to the blade bracket H Insert a screw into the blade bracket H Repeat for the two remaining screws AA Tighten each screw securely Repeat these steps for the remaining blades Fasten the blade ass...

Page 13: ...bly E on the switch cup and turn clockwise until it locks Tighten the three screws that were loosened in the first step to secure the light kit fitter assembly E Remove the bottom cover and the finial...

Page 14: ...ting your comfort NOTE Wait for the fan to stop before reversing the direction of blade rotation WARNING To reduce the risk personal injury Do not bend the blade holders while installing balancing the...

Page 15: ...ove the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same...

Page 16: ...Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use...