Installation (continued)
6
Using quick connects
7
Connect wiring from unit to house
WARNING:
Wiring must comply with all applicable electrical
codes. Turn OFF power before removing or installing
connectors.
WARNING:
COPPER TO COPPER ONLY. Do not use on
Aluminum wire.
CAUTION:
Accessory part AA (quick connect) should meet
installation instructions below.
NOTE
: Connector is reusable on solid wires of the same wire
gage or smaller. Do not reuse connector on stranded wires.
□
Strip the wires so half of the bare wire is showing.
□
Grip the wire firmly and push the stripped end of
the wire into the open port of connector (AA). Use
only one stripped end of the wire per port.
□
Verify the stripped end of the wire is fully inserted
to the back of the connector (AA).
NOTE
: Important wire information. Maximum temperature
rating 105°C (221°). 600 volts maximum for building wire and
1000 volts maximum in signs and lighting fixtures.
Flammability rating of the wires must meet UL94-V2. The
acceptable wire range includes: Solid: 12-20 AWG,
Stranded: 12-16 AWG (
≤
19 STRAND); 18AWG (7 STRAND),
Tin bonded: 14-18 AWG (
≤
19 STRAND).
WARNING:
Follow all local electrical and safety codes.
CAUTION:
Never place a switch where it can be reached
from a tub or shower.
□
Connect wires using the quick connector (AA) or
wire nut (not provided).
□
Connect the green (or bare) ground wire to the
green ground lead.
□
Connect the black wire from the unit to the house
120VAC line in (L).
□
Connect the white wire from the unit to the house
120VAC line in (N).
CAUTION:
If your house wires do not match these colors,
determine what each house wire represents before
connecting. You may need to consult a licensed electrician to
determine this safely.
Yellow
Yellow
Yellow
Blue
Red
Brown
Light
switch
Fan
switch
L(Black)
N(White)
GRD(Green)
Unit
Line in
Switch box
120 VAC
Night light
switch
Light
Night
light
Fan
Product wires
House wires
AA
WARNING:
Failure to wire product correctly could result in
electrical shock, fire hazards, or damage to the product.
Consult a licensed electrician if you are unsure of your ability
to correctly install wiring.
www.hamptonbay.com
9
Please contact 1-877-527-0313 for further assistance.
SHEET 9 TO 10