Assembly - Standard Ceiling Mount
Routing the wires
Assembling the fan
Preparing for mounting
□
Remove the canopy bottom cover (C) from the canopy (B) by
turning the bottom cover counterclockwise until it unlocks.
□
Loosen the two canopy screws (FF) located in the
bottom of the mounting bracket (A), and turn the canopy
counterclockwise to remove the mounting bracket (A) from
the canopy (B).
□
Route the wires exiting the top of the fan motor (F), through
the coupler cover (E) and canopy bottom cover (C).
□
Make sure the slot openings are on top and route the wires
through the canopy (B) and then through the ball/downrod
assembly (D).
2
3
1
□
Remove the set screw (RR) by turning it counterclockwise.
□
Install the downrod (D) by inserting it into the motor collar (TT),
and turning it clockwise until it is tight.
□
Reinstall the setscrew (RR) turning clockwise until tight.
NOTE:
This fan is equipped with a safety tab (SS). Should
the setscrew (RR) ever become loose while the fan is
running in reverse, the safety tab (SS) will engage and
stop the fan from falling.
CAUTION:
To ensure wobble-free operation and to avoid
damage to the fan, the downrod (D) and the setscrew
(RR) must be completely tightened