Switch Usage Instruction
CLOSE
AAA
OPEN
The gas pressure regulator provided with this appliance must
be used. This regulator is set for an outlet pressure of 11 inches
water column.
TYPES OF GAS PROPANE GAS
Min.Gas supply for input Adj. 25 psi
Maximum Inlet Pressure 250 psi
Manifold Pressure 11 in.w.c
Gas Rating 46,000 Btu/hr
OFF/Arrêt
LOW/
Min.
HI/
Max.
ON/
Allu-
mage
OFF/ Arrêt
OFF/Arrêt
LOW/
Min.
HI/
Max.
ON/
Allu-
mage
OFF/ Arrêt
19
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
OPERATION
1
Open the igniter button and install an AAA battery
(not included), then secure the cap back on. Before
use, make sure that the control knob is in the “OFF”
position. Turn the LP cylinder gas valve to fully open
position. Press down on the control knob and turn
counter clockwise to the "LOW" position. Push in the
gas control knob all the way and hold. Continue to
press the ignition button for 15 seconds.
If the burner is not lit, press down the control knob
and turn clockwise to the "OFF" position. Repeat step
1 after 5 minutes. When the burner is lit, press down
the control knob and turn it to the desired heat output
position between “LOW” and “HIGH”. Press down
and turn the control knob clockwise to the "OFF"
position to shut down the appliance.
Turn off the cylinder gas valve.
Lighting
2
Adjusting and Shutting Down
To extinguish the flame, push the control knob in and rotate clockwise.
NOTE:
Care and Maintenance
Do not use aerosol polish or any other flammable material to clean the burner while it is in use.
Inspect and clean the burner regularly. Use a wire-bristle brush to clean the burner surface. A straightened paper clip is useful to remove
debris or rust from the small burner ports.
Wash frame parts with mild soap and water, rinse thoroughly, and dry completely. Do not use bleach, acid, or any other solvents on the
frame parts.
Inspect and tighten all of the bolts and fasteners on a regular basis to ensure the proper performance and safety of your appliance.
When not in use, we recommend that it be stored in a dry and secure area. Always disconnect the LP gas tank first and store it safely outside.
The minimum clearance from the sides, rear, and top of unit to adjacent combustible construction: 2' (61 cm) from the sides, 2' (61 cm) from the rear, and 5'
(152.5 cm) from the top.
Improper lighting operations will cause serious injury and explosion.
Caution