background image

 4 
 

Pre-installation  

 

 

 

        

       
 

 
 
 

  TOOLS REQUIRED  

 

 

Claw hammer 

 
 
 
 

Electrician 
knife  

 

 
Phillips 
screwdriver 
 
 
 
 

 

 

 

HARDWARE INCLUDED  

 

 

NOTE: Hardware not shown to actual size. 

 

 

   PACKAGE CONTENTS 

            

 

WARNING:

  Use only CSA or UL approved low-voltage 

cable. Failure to use at least 16 gauge minimum cable 
or install it as directed in these instructions may result 
in Risk of Fire or Electric Shock. Using large cable will 
ensure maximum light output. 

Part 

Description 

Quantity 

A Transformer 

B Photocell 

C Mounting 

Template 

Hardware pack 

y

 

AA Screw 4.8X30.    (QTY 4)  

y

 

BB Screw 3.5X15     (QTY 2) 

y

 

CC Wall anchor        (QTY 4) 

Summary of Contents for 1001 509 809

Page 1: ...nce your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Item 1001 509 809 Model SL 200 12A USE AND CARE GUIDE TRANSFORMER Questions problems missing parts Before returning to the store call HamptonBay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM ...

Page 2: ...re experiencing problems contact a qualified electrician WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide re...

Page 3: ... set up or used in any way not in accordance with the instructions supplied with the product This warranty shall not apply to a failure of the product as a result of an accident misuse abuse negligence alteration or faulty installation or any other failure not relating to faulty material or workmanship This warranty shall not apply to the finish on any portion of the product such as surface and or...

Page 4: ...L approved low voltage cable Failure to use at least 16 gauge minimum cable or install it as directed in these instructions may result in Risk of Fire or Electric Shock Using large cable will ensure maximum light output Part Description Quantity A Transformer 1 B Photocell 1 C Mounting Template 1 D Hardware pack y AA Screw 4 8X30 QTY 4 y BB Screw 3 5X15 QTY 2 y CC Wall anchor QTY 4 1 ...

Page 5: ... on the transformer Lay the transformer on a flat stable surface and insert the stripped end of one wire under the terminal clamping plate COM Then tighten the screw Repeat this procedure for clamping plate 12V or 15V See cable selection chart for correct voltage tap NOTE Gently pull on the landscape wire to verify if the connection is strong NOTE Verify that there are no loose cable strands WARNI...

Page 6: ...re Be sure to leave minimum of 10 feet 3m of wire between the power pack and first fixture Turn the transformer on Attach your fixtures to the cable to using cable connectors as shown Place one connector on each side of the cable then press together to lock Prongs will pierce the cable to make contact and your fixtures should light up Turn the transformer on Attach your fixtures to the cable using...

Page 7: ...s will have the transformer come on when it has become darker out The location position and orientation of the photocell can be adjusted until the transformer turns on at the desired light level If the wires to the photocell are cut or broken the photocell can be replaced Unscrew the photocell connector cover from the transformer and pull the bi pin connector out of the mating socket The replaceme...

Page 8: ... off the lights 3 Setting PHOTOCELL AUTO ON OFF 4 Setting PHOTOCELL ON TIME OFF This setting allows the photocell to turn the lights on at dusk and off at dawn a Press MENU until the PHOTOCELL AUTO ON OFF LED indicator is lit and then press OK The PHOTOCELL AUTO ON OFF mode is now activated The digit display shows the current time and the AM PM LED indicator stays lit b The start delay time is 0 1...

Page 9: ...ling the external light signal the lights will turn on at dusk and off at dawn within 0 5 seconds NOTE When using the TEST function during daylight hours with the photocell installed on the transformer be sure to completely cover the photocell for the lights to turn on The photocell needs to sense darkness in order to function even in TEST mode If no photocell is installed on the transformer the l...

Page 10: ...n chart 12 VOLT TAP Cable Length Total Fixture Wattage 0 50 feet 51 100 feet 101 150 feet 0 60 Watts 16 AWG 16 AWG 14 AWG 61 120 Watts 16 AWG 14 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not recommended 181 240 Watts 14 AWG 12 AWG Not recommended 240 300 Watts 12 AWG Not Recommended Not recommended 600W 2x300 Watts 12 AWG Not Recommended Not recommended 900W 3x300 Watts 12 AWG Not Recommended Not rec...

Page 11: ...ns problems missing parts Before returning to the store call HamptonBay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use ...