Check Battery
Check battery electrolyte level and clean terminals
every 100 hours.
1. Turn battery disconnect to the OFF position.
2. Ensure that no ignition sources are near
batteries.
3. Loosen and remove battery cable clamps
carefully,
negative
(-)
cable first.
4. Clean cable clamps and terminals to remove
dull glaze.
5. Check for signs of internal corrosion in cables.
6. Remove cell caps
7. Fill each cell with distilled water, replace cell
caps.
8. Connect battery cable clamps,
positive (+)
cable first.
9. Tighten any loose connections.
10. Ensure that battery tiedowns are secure.
11. Turn battery disconnect to the ON position.
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
To help avoid injury:
•
Wear safety glasses and face shield and rubber gloves.
•
Use flashlight to check electrolyte level.
•
Work in a well-ventilated area.
•
Avoid breathing fumes from battery, and avoid contact with skin, eyes, or clothing.
•
Keep flames and sparks away.
•
Keep out of reach of children.
•
Do not short across battery terminals or allow tools to short from battery terminals to frame.
•
Do not jump-start or charge a battery with frozen electrolyte.
NOTICE:
In freezing weather, run the engine immediately after filling battery to allow water and
electrolyte to mix.
j64om045w.eps
Summary of Contents for HG2200
Page 51: ...HG2200 HG2200AT Operator s Manual Battery Disconnect 50 Controls ...
Page 75: ...HG2200 HG2200AT Operator s Manual Retrieve Tracked Unit 74 Transport ...
Page 87: ...HG2200 HG2200AT Operator s Manual Finish Installation 86 Burst Pipe ...
Page 129: ...HG2200 HG2200AT Operator s Manual As Needed 128 Service ...
Page 133: ...HG2200 HG2200AT Operator s Manual Declaration of Conformity Information 132 Specifications ...
Page 137: ...HG2200 HG2200AT Operator s Manual 136 Service Record Service Performed Date Hours ...
Page 146: ......