background image

33

This function allows you to extract only a predefined 

number of characters when reading a barcode.

To set the intercept start and stop character, proceed 

as follows.

1. Scan “Enter/Exit Programming Mode” barcode.

2. Scan “Data intercept start digit” barcode.

3. Enter the 3-digit start number using 0 to 9 barcodes 

in the Parameters Table.

4. Scan “Data intercept stop digit” barcode.

5. Enter the 3-digit start number using 0 to 9 barcodes 

in the Parameters Table.

6. Scan “Intercept from left to right” or “Intercept from 

right to left” barcode. 

7. Scan  “Enter/Exit Programming Mode” barcode to 

complete setting.

For example. If barcode is “0123456” and you want to 

take “234” digits only, that means start digit will be the 

3rd character and stop digit the 5th.

So setting for start and stop digit will be:

Data intercpet start digit: “0”, “0”, “3”

Data intercpet stop digit: “0”, “0”, “5”

Data Intercept

Estrazione Dati Parziale

Summary of Contents for HBCS1D360

Page 1: ...www hamletcom com HBCS1D360 USER MANUAL MANUALE UTENTE FOR LINEAR CODES 1D BARCODE SCANNER 360 OMNIDIRECTIONAL ...

Page 2: ...slative Decree 2005 151 and EMC Directive 2014 30 EU for the following standards EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 The complete CE declaration of conformity of the product can be obtained by contacting Hamlet at info hamletcom com Visit www hamletcom com for complete information on Hamlet products and to access downloads and technical support Imported ...

Page 3: ...5 EU RAEE 2002 96 CE 2003 108 CE D lgs 151 2005 e dalla Direttiva EMC 2014 30 EU per i seguenti standard EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 La dichiarazione di conformità CE completa relativa al prodotto può essere richiesta contattando Hamlet all indirizzo e mail info hamletcom com Visita www hamletcom com per informazioni complete su tutti i prodotti ...

Page 4: ...seguenti informazioni sono fornite all utente CLASSE 1 APPARECCHIO LASER DI CLASSE 1 CLASSE 2 RADIAZIONE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 Laser Devices Hamlet products using lasers comply with IEC 60825 1 EN 60825 1 2014 The laser classification is marked on one of the labels on the product Class 1 Laser devices are not considered to be hazardous when used for their intend...

Page 5: ... Tone 16 Beeper Duration 17 Beeper Volume 18 RS 232 Interface 20 Baud Rate 20 Stop Bit 23 Keyboard Language 24 Capital Lock 27 Function Key Emulation 28 Data Edit 29 Prefix and Suffix 29 Terminator Setting 31 Data Intercept 33 Add Code Length 37 Barcode Configuration 38 Parameters Table 51 CONTENTS SOMMARIO ...

Page 6: ...mplified version of user manual For detailed information please download the complete user manual at hamletcom com Questa è una versione semplificata del manuale Per informazioni dettagliate potete scaricare il manuale completo dal sito hamletcom com ...

Page 7: ...r modificare le impostazioni dello scanner proce dere come indicato di seguito 1 Scansionare il codice a barre Entra Esci Modalità Programmazione Vengono emessi 2 beep basso alto per indicare che lo scanner è pronto per le nuove impostazioni 2 Scansionare il codice a barre dell impostazione desiderata 1 beep 3 Scansionare di nuovo il codice Entra Esci Modalità Programmazione per salvare le imposta...

Page 8: ...8 RESET RIPRISTINO Reset Ripristino impostazioni di fabbrica Interfaccia PC AT USB predefinita Default Value Valore Predefinito ...

Page 9: ...9 SYSTEM INTERFACE SETTINGS IMPOSTAZIONI INTERFACCIA Interfaccia Automatica Interfaccia RS 232 predefinita ...

Page 10: ...r life time requires device support for this function In questa sezione l utente può impostare il laser e o il motore per entrare in modalità sleep stand by I codici a barre consentono all utente di impostare un intervallo di tempo prima che il laser e o il motore entri in modalità stand by Questa funzione riduce il consumo energetico e prolunga la vita dello scanner richiede il supporto del dispo...

Page 11: ...11 Motor Sleep Time Tempo Stand by Motore ...

Page 12: ...12 Laser Sleep Time Tempo Stand by Laser ...

Page 13: ...13 Scan Code Delay Time Tempo di Ritardo Scansione ...

Page 14: ...14 Non permette la continua lettura dello stesso codice Permette la continua lettura dello stesso codice ...

Page 15: ...15 Suono di accensione attivo Suono di accensione disabilitato Beeper Setting Impostazione Segnale Acustico ...

Page 16: ...16 Tono Alto Tono Medio Tono Basso Beeper Tone Tono Segnale Acustico ...

Page 17: ...17 Speaker disattivato Durata Breve Durata Media Beeper Sound Duration Durata Segnale Acustico ...

Page 18: ...18 Durata Lunga Volume Alto Beeper Volume Volume Segnale Acustico ...

Page 19: ...19 Volume Medio Volume Basso ...

Page 20: ...20 1200 2400 RS 232 INTERFACE INTERFACCIA RS 232 Baud Rate Velocità Baud ...

Page 21: ...21 4800 9600 19200 ...

Page 22: ...22 38400 57600 115200 ...

Page 23: ...23 Stop Bit Bit Stop ...

Page 24: ...24 Keyboard Language Lingua Tastiera ...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...27 Conversione Attiva Blocco Maiuscolo Off Capital Lock Blocco Maiuscolo ...

Page 28: ...28 Attiva Emulazione Tasto Funzione Disattiva Emulazione Tasto Funzione Function Key Emulation Emulazione Tasto Funzione ...

Page 29: ...a lunghezza massima per Prefisso Suffisso è di 10 caratteri Per impostare un Prefisso Suffisso personalizzato seguire i passaggi seguenti 1 Scansionare il codice a barre Entra Esci Modalità Programmazione 2 Scansionare il codice Prefisso o Suffisso 3 Eseguire la scansione del codice a barre dall elenco ASCII fare riferimento al manuale utente completo 4 Scansionare il codice a barre Entra Esci Mod...

Page 30: ...30 Prefisso Suffisso ...

Page 31: ...31 Nessuno Tabulazione Terminator Setting Impostazione Inserimento ...

Page 32: ...32 Invio Spazio Ritorno a capo ...

Page 33: ...ta intercept stop digit barcode 5 Enter the 3 digit start number using 0 to 9 barcodes in the Parameters Table 6 Scan Intercept from left to right or Intercept from right to left barcode 7 Scan Enter Exit Programming Mode barcode to complete setting For example If barcode is 0123456 and you want to take 234 digits only that means start digit will be the 3rd character and stop digit the 5th So sett...

Page 34: ...l codice Carattere fine estrazione 5 Inserire il numero di fine estrazione 3 cifre utilizzando i codici a barre da 0 a 9 nella Tabella dei Parametri alla fine del manuale 6 Scansionare il codice a barre Intercetta da sinistra a destra o Intercetta da destra a sinistra 7 Scansionare il codice a barre Entra Esci Modalità Programmazione per completare l impostazione Per esempio Se il codice a barre è...

Page 35: ...35 Disabilita Estrazione Dati Parziale Estrazione da sinistra a destra Estrazione da destra a sinistra ...

Page 36: ...36 Carattere inizio estrazione Carattere fine estrazione ...

Page 37: ...37 Attiva Aggiungi Lunghezza Codice come Intestazione Tutti i codici a barre Disattiva Aggiungi Lunghezza Codice come Intestazione Tutti i codici a barre Add Code Length Aggiungi Lunghezza Codice ...

Page 38: ...38 BARCODE CONFIGURATION CONFIGURAZIONE BARCODE Enable Attiva Disable Disattiva ...

Page 39: ...39 ...

Page 40: ...40 ...

Page 41: ...41 ...

Page 42: ...42 ...

Page 43: ...43 ...

Page 44: ...44 ...

Page 45: ...45 ...

Page 46: ...46 ...

Page 47: ...47 ...

Page 48: ...48 ...

Page 49: ...49 ...

Page 50: ...50 Black and White Inverse Code Reading ON Lettura Codice Bianco e Nero Invertito ON Black and White Inverse Code Reading OFF Lettura Codice Bianco e Nero Invertito OFF ...

Page 51: ...51 PARAMETERS TABLE TABELLA PARAMETRI 0 1 ...

Page 52: ...52 2 3 4 ...

Page 53: ...53 5 6 7 ...

Page 54: ...54 8 9 ...

Page 55: ...Entra Esci Modalità Programmazione ...

Reviews: