Page 28
BK745
Hamlet Solution Inset (S4) Stove User Guide
TECHNICAL DATA
Solution 5kW
Inset S4
Solution 7kW
Inset S4
Nominal Heat Output—Wood (Kw)
5.0
7.1
Efficiency Nett At Nominal Heat
Output (%)
79.9
75.4
Mean Flue Gas Temperature (°C)
274
326
Mean CO Emission @ 13% O2 (%)
0.08
0.11
Flue Mass Gas Flow (g/s)
4.1
6.23
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (Seasoned Hardwood)
1.44
1.62
Mean CH Emission @ 13% O2 (%)
79
92
Mean NOx Emission @ 13% O2 (%)
97
95
DIN Plus Particulates @ 13% O2 (%)
14
27
Ideal Log Length & Diameter (mm)
200 / 100
300 / 100
Nominal Heat Output—Solid fuel (Kw)
5.0
7.1
Efficiency Nett At Nominal Heat
Output (%)
76.0
75.8
Mean Flue Gas Temperature (°C)
323
332
Mean CO Emission @ 13 % O2 (%)
0.07
0.08
Flue Mass Gas Flow (g/s)
4.1
6.4
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (MSF Maxibrite)
0.76
1.08
Mean CH Emission @ 13% O2 (%)
30
43
Mean NOx Emission @ 13% O2 (%)
138
159
DIN Plus Particulates @ 13% O2 (%)
12
27
TECHNICAL SPECIFICATION