background image

BK540  

EN 13240:2001+ 

Amd. A2 

February 2013

 

PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE

 

User Guide 

For stove ranges: 

Camborne Deluxe - Generation 2 

Hardy 4 & 5 - Series 4 

Solution - Series 2 

Summary of Contents for BK540

Page 1: ...BK540 EN 13240 2001 Amd A2 February 2013 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE User Guide For stove ranges Camborne Deluxe Generation 2 Hardy 4 5 Series 4 Solution Series 2...

Page 2: ...ances including multi fuel stoves If in doubt contact The Solid Fuel Association telephone 0845 601 4406 01773 835400 or visit www solidfuel co uk It is a legal requirement that the installation of al...

Page 3: ...a chimney fire Please Note If you have sticky tar inside the appliance or chimney your wood is green or too wet PAPER Paper will burn successfully Burn dry paper only or chimney damage will occur WARN...

Page 4: ...ating the air controls Your stove has two air inlet controls These may be located either on the stove body or the door The primary air inlet providing under draught to the base of the fire chamber and...

Page 5: ...e off fumes which are non toxic but certain persons may find they have an unpleasant or irritant effect Ensure that the surrounding area is well ventilated during this time BURNING SOLID FUELS Only ap...

Page 6: ...any damaged bars replaced Also check for obstructions that may prevent the operation of the riddling mechanism DOOR GLASS The door glass should remain clear during normal burning However under certai...

Page 7: ...d up to touch the underside of the grate bars as this will greatly reduce the life span of the grate The ash will require less frequent removal when burning wood compared to solid fuels WARNING The as...

Page 8: ...he fire door can be re aligned as follows 1 When the appliance is cold open the fire door so that it is at right angles to the front of the stove 2 Lift the fire door up off its hinges 3 Gently tap th...

Page 9: ...oduced in the event of a claim being made Claims are not valid where installation does not conform to appropriate building regulations The manufacturers decision shall be final However if your applian...

Page 10: ...151 4 424 163 4 94 33 4 6 Solution 7 Series 2 1 5 6 558 22 476 183 4 386 15 449 171 2 109 41 2 6 Solution 9 Series 2 2 9 600 231 2 586 23 396 151 2 485 19 103 4 7 Solution 11 Series 2 2 5 11 605 233 4...

Page 11: ...364 0 68 AIB9 6 4 2 6 51 2 800 500 152 6 74 7 670 0 71 AIB10 7 6 3 4 Flue Diameter mm inches Nett Efficiency Mean Flue Gas Temperature Mean CO Emissions 13 O2 Add in Boiler If Available 6 Rectangular...

Page 12: ...Plate Door Catch Door Handle Operating Tool Stove Glove Grate Fuel Bed Installation Guide Assembled By Checked by Model The Fireworks Weycroft Avenue Axminster Devon EX13 5HU www arada uk com www arad...

Reviews: