Register
Number
XVG/eXVG Parameters
Name
Write
Access
Description Type
3014
IDM_ADCINPRES
RO
Input Pressure counts, range 0-4095
U16
3015
IDM_ADCAI0
RO
Analog Input 0 (demand), range 0-3413
U16
3016
IDM_ADCOUTPRES
RO
Output Pressure counts, range 0-4095
U16
3017
IDM_ADCAI1
RO
Analog Input 1 counts, range 0 – 4095
U16
3018 IDM_ADCDELTAPRES
RO Not
used
U16
3019
IDM_ADCAI2
RO
Analog Input 2 counts, range 0 – 4095
U16
3020
IDM_ADCGASTEMP
RO
Gas Temperature counts
U16
3021
IDM_ADCAI3
RO
Analog Input 3 counts, range 0 – 4095
U16
3022 IDM_ADCSOLTEMP
RO
Solenoid temp counts, not used
U16
3023
IDM_ADCAI4
RO
Analog Input 4 counts, range 0 – 4095
U16
3024
IDM_ADCMOTORCUR
RO
Motor Current counts, range 0 - 4095
U16
3025
IDM_ADCAI5
RO
Analog Input 5 counts, range 0 – 4095
U16
3026
IDM_FFAULTFLGS
RO
Fault Report Variable, not used
U16
3027
IDM_FVERSION
RO
Fault Report Variable, not used
U16
3028
IDM_FRUNTMMINS
RO
Fault Log, Run Time Minutes of fault log
U16
3029
IDM_FRUNTMSECS
RO
Fault Log, Run Time Seconds of fault log
U16
3030
IDM_SETUPERROR
RO
Setup Validation Error Code, 0 = No Errors
U16
3031
IDM_TESTFLAGS
W3
Test Flags (SW debug use only)
U16
3032
IDM_FMODE
RO
Fault Report Variable, not used
U16
3033 IDM_CALFLAGS
W1
Calibration Flags:
Bit0=Set Valve in Calibration State.
The following bits active only in cal state:
Bit1=Enable Feedback Override,
Bit2=Set Solenoid Duty Cycle Out to 50%
Bit3=Read ADC A raw cal voltage into
IDM_ADCACALADC
Bit4=Read ADC B raw cal voltage into
IDM_ADCBCALADC
Bit5=Write parameters to EEPROM Bit6=Reset
IDM_TOTALHRS to 0 if parameter IDM_DATE =
666
U16
3034
IDM_CALAOUT0
W3
Analog Output 0 DAC Value, counts 0-4095
U16
3035
IDM_ADCBCALADC
RO
ADC B 2.5V Ref Calibration counts 0-4095
U16
3036
IDM_AOUT1
W3
Analog Output 1 DAC Value, counts 0-4095
U16
3037
IDM_AOUT2
W3
Analog Output 2 DAC Value, counts 0-4095
U16
3038 IDM_FIRMWAREVER
RO Firmware
Version
U16
3039
IDM_AOUT0
RO
AO0 DAC Value, counts 0-4095
U16
3040 IDM_DIN0
RO
DI0 Value: (reserved for external Run/Stop)
Bit0-Bit3=DI0-DI3 – only used if valve enters
CAL_STATE
U16
3041 IDM_DOUT0
W3
Digital Output 0 Value: (reserved for Fault Output)
Bit0-Bit5=O0-O3, 485TXENA, 485TXENB – only
valid if valve enters CAL_STATE, otherwise for SW
test
U16
25