background image

8 | Hamilton Beach Owner’s Manual

Hamilton Beach Owner’s Manual | 9 

 Detailed Installation Instructions

General Installation Warnings

The following general warnings should be observed when 

installation and/or general service maintenance is performed.

•  Plumbing connections should be done in 

accordance with state and local plumbing codes.

•  Do not use with water that is microbiologically 

unsafe or of unknown quality without adequate 
disinfection before or after the system.

•  Drain lines should be 1⁄2” minimum for drain line 

flows up to 7 gpm. Flows above 7 gpm or runs in 
excess of 20 feet require 3⁄4” drain line.

WARNING: Never connect drain line directly into a drain, sewer line or 
trap. Plumbing code requires installation to allow an air gap* between the 
drain line and the wastewater to prevent the possibility of sewage back-
siphoning into the conditioner. (See Figure 6.) Sewage backup can have 
harmful health effects.

* Plumbing code air gap is one inch above the flood plane.

•  All electrical connections must be connected 

according to local codes. The electrical source 
must be uninterrupted. Install grounding strap on 
metal pipes.

•  Do not use pipe dope or other types of liquid 

sealants on any threads. Teflon tape must be used 
on the drain line 3⁄4” threads and also on the 

3

/

8

” 

brine-line connections.

 

Note: Factory has teflon taped these fittings.

•  Use caution if soldering inlet, outlet, or drain lines. 

Excess heat will damage the control valve and/or 
bypass valve.

•  A Brine Tank over-flow line of 1⁄2” ID 

5

/

8

” OD is 

recommended for the brine tank. This line should 
run from the barb fitting on the side of the tank to 
an unobstructed drain. (See Figure 7.)

•  Each system comes standard with a high-pressure 

injector.* It may be necessary to change the 
injector (see Figure 8) to match your incoming 
water pressure. (See Table 2 for injector sizes.)

 

*Standard Injector (High Pressure) 

Detailed Installation 
Instructions

Injector Selection

Water Pressure

Injector

Part Number

20–60 psi

(138–414 bar)

AVP-1032980 (#5 Injector)

61–120 psi

(420–827 bar)

AVP-1032977 (#4 Injector)

Table 2: 

Injector selection based on water pressure.

Figure 6:

 Correct air-gap installation.

Overflow fitting 
installed

Connect 

1

/

2

” (1.3 cm) ID tubing 

or hose and run to drain.

Brine tank

Figure 7:

 Brine tank tubing connection with overflow fitting.

Figure 8: 

Injector screen and cap installation.

Injector

Injector cap

Injector 

Summary of Contents for SA-HB-40-DB-CERT

Page 1: ...Models SA HB 40 DB CERT SA HB 48 DB CERT Water Softener Made with Pride in the USA DuraResin Blend...

Page 2: ...quality without adequate disinfection before or after the system pn LBL HB 48 CERT MODEL SA HB 48 CERT Water Softener Operating Temperature 34o 120o F Operating Pressure 20 60 psi 5 injector 61 120 ps...

Page 3: ...8 Pre Installation Checklist 8 Detailed Installation Instructions 9 Start Up Rinsing Procedure 10 Battery Backup Feature 12 Programming the Control Valve 12 Level I Programming 13 Level I Programming...

Page 4: ...102 to 132 vac 60 Hz Current 50 mA Transformer Wall Mount indoor use only Operating Temperature 34o F to 120o F Humidity 10 to 100 Condensing Allowed Service Connections 3 4 1 11 4 Copper Tube Adapter...

Page 5: ...__________Other ____________ __________Other ___________ All Water is treated except ___Front hose bib __Rear hose bib ___Kitchen ___Toilets ____Other___________________________________________ Sizin...

Page 6: ...its sodium state Proportionate Brining Your Hamilton Beach System utilizes an advanced microprocessor to control the amount of regenerant proportionate to the amount of exhausted resin It uses enough...

Page 7: ...clean the tank disconnect the brine line connection rinse out any insoluble build up reconnect the brine line and add one inch of fresh water Then totally refill the tank with salt Setting Time Clock...

Page 8: ...0907 see pg 11 o Drain Line Connection Choose a location close to a drain to put your brine tank Avoid overhead runs in excess of 25 feet Drain line must be a minimum of 1 2 inside diameter Manual Byp...

Page 9: ...ounding strap on metal pipes Do not use pipe dope or other types of liquid sealants on any threads Teflon tape must be used on the drain line 3 4 threads and also on the 3 8 brine line connections Not...

Page 10: ...the drain during this procedure Figure 9 Inlet Outlet Figure 12 Once the air clears and water begins to run to the drain open the inlet valve only to the full open position and allow the water to run...

Page 11: ...ol valve to the service position See Figure 14 7 Plug in the control valve See Figure 15 8 If it is necessary to extend the length of the transformer cord an optional 15 foot 4 6 m extension cord is a...

Page 12: ...power for shorter periods of time The control can be operated without a battery but the control will not measure water usage or time while the power is off The control will save all important operati...

Page 13: ...ng with the time of day Pressing the up arrow button displays the settings in reverse order Level I Programming Parameters P1 Time of Day AM or PM Ranges 1 00 to 12 59 or 00 00 to 23 59 Minimum Increm...

Page 14: ...in to enter the value Time of Regeneration The next value displayed is the Time of Regeneration which is similar to Time of Day programming It has a default setting of 2 00 a m If 2 00 a m is acceptab...

Page 15: ...n a n a P9 Backwash time 3 30 1 Minutes Skip this parameter to accept the default or enter a value P10 Slow rinse time 8 125 1 Minutes SA HB 40 DB CERT 67 SA HB 48 DB CERT 80 P11 Fast rinse time 2 19...

Page 16: ...bump injector 7 5 lbs 26 min w 4 bump injector 15 0 lbs 51 min w 4 bump injector 4 0 lbs 9 min w 5 bump injector 9 0 lbs 31 min w 4 bump injector 18 0 lbs 61 min w 4 bump injector P8 Not used n a n a...

Page 17: ...a 42 0 22 0 n a 43 0 23 0 n a 44 0 24 0 n a 45 2 25 0 n a 45 9 26 0 n a 46 5 27 0 n a 47 2 28 0 n a 48 0 Table 8 System capacity by pounds of salt 40 SA HB 40 DB CERT certified capacity at salt settin...

Page 18: ...18 Hamilton Beach Owner s Manual Flow Diagrams Flow Diagrams Figure 20 Figure 21 Figure 22 Figure 23...

Page 19: ...Hamilton Beach Owner s Manual 19 Flow Diagrams Figure 24 Figure 25 Figure 26...

Page 20: ...20 Hamilton Beach Owner s Manual Control Valve Diagram Control Valve Diagram...

Page 21: ...Assembly 1 10 AVP 1032977 AVP 1032980 Injector Assembly 4 Bumps Injector Assembly 5 Bumps 1 11 AVP 1032985 Injector Cap Assembly 1 12 AVP 1010140 O Ring 1 x 1 1 4 x 1 8 inch 1 13 AVP 1010129 O Ring 1...

Page 22: ...opper Tail Kit 1 1 4 Copper Tail Kit 3 4 CPVC Tail Kit 1 CPVC Tail Kit 1 13 BP A 1040930 Hamilton Beach Bypass 1 14 BTC 1423 Brine Tank Lid 1 SA HB 48 DB CERT Code Part Number Description Qty 1 AUV 10...

Page 23: ...seconds For additional troubleshooting information see the troubleshooting guide Table 10 which may help determine the problem and potentially solve the problem If consulting the troubleshooting guid...

Page 24: ...ter meter maintenance section Defective meter probe Replace control Defective circuit board Replace control Control display is frozen at REGEN TIME REMAINING Back to back regenerations were requested...

Page 25: ...er pressure Increase water pressure 20 psi at conditioner Restricted drain line Remove obstruction Injector or injector screen is plugged Clean injector and screen refer to the Cleaning the Injector I...

Page 26: ...en by foreign matter Manually operate cam gear to flush out foreign matter holding disc open Weak valve stem return spring on top plate Replace spring Resin in valve Clean valve and backwash control H...

Page 27: ...Hamilton Beach Owner s Manual 27 Notes...

Page 28: ...28 Hamilton Beach Owner s Manual Notes...

Page 29: ...Hamilton Beach Owner s Manual 29 Notes...

Page 30: ...30 Hamilton Beach Owner s Manual Notes...

Page 31: ...Hamilton Beach Owner s Manual 31 Notes...

Page 32: ...R M Water Group Water Technologies Inc and R M Water Group are branded trademarks of Water Technologies Inc All rights reserved Material produced by Water Technologies Inc and authorized by Hamilton...

Reviews: