7
Care and Cleaning of the Mixer
w
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts before operating.
Failure to do so can result in death
or electrical shock.
5.
Carefully lower the
new motor/agitator
assembly into the
housing, guiding the
spindle through the
hole in the housing.
Align the rounded
indent on the front of the rubber support with the
front screw boss in the housing.
6.
Plug the two halves
of the plug connector
together, ensuring
that all lead wire col-
ors match, and tuck
the connector into the
back of the housing.
Make sure that the side clips on the plug halves
engage.
NOTE:
The plug will only connect together
in one way.
7.
Make sure that all wires are out of the way and
that they cannot come in contact with the motor.
Then lower the cover into place, making sure that
the upper tab and seal of the back panel are in
place below the lip of the cover. Secure the cover
with the screws.
8.
Plug mixer into a grounded outlet.
Motor Replacement
1.
Unplug mixer.
2.
Loosen the three
screws in the top
cover (the screws
will remain in the
cover). Lift off the
top cover and rest
against the rear
panel of the mixer.
3.
Squeeze the tabs
on the sides of the
connector plug and
pull the two plug
halves apart.
4.
Lift the motor/
agitator assembly
straight up and out
of the housing.
Discard the motor
assembly in an
environmentally
acceptable manner that complies with Federal,
State and local waste management regulations.
To replace the motor, follow the steps below, or call an authorized service center.
Single Spindle Drink Mixer shown for illustration purposes.
Please follow the same procedure for Triple Spindle Drink Mixer.
For assistance or replacement parts, call
our Technical Service number:
866-285-1087
or
910-693-4277
8:00 a.m. – 5:00 p.m. EST Monday – Friday
www.commercial.hamiltonbeach.com
Technical Service