4
OPERATION
● Ambient temperature
● Temperature 0-35°C
● Atmosphere 86-106 kpa
● VOLTAGE:115V/60HZ
● Put the water cooler on the horizontal ground. Leave an adequate space (10-20 cm)
behind the water cooler for good ventilation.
● When using the bottles with pure water, remove the cap of the water bottle. Open the
water dispenser door, you can see a pipe. Then put the pipe into the water bottle, and
make sure the cap covers the bottleneck tightly, to avoid the water can't be pumped
into the water tank.
● Push the hot water tap, and bubbles are generated inside the bottle. It says that water
is flowing into a hot water tank and cold water tank. Keep pressing the hot water tap
until water flows out. Coldwater doesn't need particular adjustments.
● Caution: Do not connect the electrical power plug, until water comes out of the hot
water tap.
● After water flows out from the hot tap, power can be on, then the hot indicator on the
front panel will be on.
●Turn the heating switch on, the red indicator on the front lights is on and the heating
system starts working, when the hot water comes up (86-95°C) or so, the red indicator
goes off. The heating system stops working, then it is on a warm keeping status.
When the hot water temperature is lower than 85°C, the heating system will start to
work again automatically.
●Turn on the cooling switch, the cold indicator on the front panel is on. The cooling
system starts working when the cold water falls between 5-10°C (for compressor-
cooling). When the cooling indicator goes off, the cooling system stops working and it
is on a cold keeping status. When the cold water temperature goes up to 10
℃
, the
cooling system will work again atomically.
● Since the temperature has already been adjusted before leaving the factory, the
customer doesn't have to set the temperature.
●Turn on the heating switch and cooling water switch on. Then the heating and cooling
processes start working. When the heating indicator is red, the heating function is on.
When the hot water temperature reaches the set limit, the heating process starts
working automatically. When the cooling indicator is green, the cold water starts
working. The cooling indicator will be off when the cold water temperature meets the
default temperature. The cooling indicator will be on when the process of cold water
starts working again. Turn on either the cold water switch or hot water switch, the
process can work separately.
● Cold and hot water: when the red indicator lights on, the heating system works. When
Summary of Contents for HBWC114-SSWH