Technical Data
Recommended accessories:
HOO10
Analysis of I
2
C, SPI and UART/RS-232 signals on analog
and logic channels
HOO11
Analysis of I
2
C, SPI and UART/RS-232 signals on all analog
channels
HOO12
Analysis of CAN and LIN signals on analog and logic channels
for two buses
HO3508 Active 8 channel logic probe
HO3516 2 x HO3508, active 8 channel logic probes
HO720
USB-device/RS-232 dual-interface card
HO740
IEEE-488 (GPIB) interface card, galvanically isolated
HZ46
4 RU 19" Rackmount kit
HZ99
Carrying case for protection and transport
HZ100
Differential probe 20:1/200:1
HZ115
Differential probe 100:1/1,000:1
HZ355
500 MHz passive probe 10:1 with automatic identification
HZ355DU Upgrade from 2 x HZ350 to 2 x HZ355
HZO20
High voltage probe 1000:1 (400 MHz, 1000 V
rms
)
HZO30
1 GHz active probe (0.9 pF, 1 MΩ, including many accessories)
HZO40
Active differential probe 200 MHz (10:1, 3,5pF, 1 MΩ)
HZO41
Active differential probe 800 MHz (10:1, 1pF, 200 kΩ)
HZO50
AC/DC current probe 30 A, DC to 100 kHz
HZO51
AC/DC current probe 100/1000 A, DC to 20 kHz
Accessories included:
HO730 Ethernet/USB dual-interface card, Line cord, printed operating
manual, 2/4 probes (amount=number of channels), 10:1 with attenuation ID
(HZ350 400/300 MHz, HZ355 500 MHz), software-CD
HO730
Built-in Ethernet/USB
dual-interface card
Printed operating manual
and software-CD
HZ350
400 MHz passive probe
(for 400/300 MHz oscilloscopes)
HZ355
500 MHz passive probe
(for 500 MHz oscilloscopes)
More information
| www.hameg.com
13
12 HAMEG INSTRUMENTS
| HMO3000 SERIES
Accessories included:
HO730 Ethernet/USB dual-interface card, Line cord, printed operating
manual, 2/4 probes (amount=number of channels), 10:1 with attenuation ID
(HZ350 400/300 MHz, HZ355 500 MHz), software-CD
HO730
Built-in Ethernet/USB
dual-interface card
Printed operating manual
and software-CD
Recommended accessories:
HOO10
Analysis of I
2
C, SPI and UART/RS-232 signals on analog
and logic channels
HOO11
Analysis of I
2
C, SPI and UART/RS-232 signals on all analog
channels
HOO12
Analysis of CAN and LIN signals on analog and logic channels
for two buses
HO3508 Active 8 channel logic probe
HO3516 2 x HO3508, active 8 channel logic probes
HO720
USB-device/RS-232 dual-interface card
HO740
IEEE-488 (GPIB) interface card, galvanically isolated
HZ46
4 RU 19" Rackmount kit
HZ99
Carrying case for protection and transport
HZ100
Differential probe 20:1/200:1
HZ115
Differential probe 100:1/1,000:1
HZ355
500 MHz passive probe 10:1 with automatic identification
HZ355DU Upgrade from 2 x HZ350 to 2 x HZ355
HZO20
High voltage probe 1000:1 (400 MHz, 1000 V
rms
)
HZO30
1 GHz active probe (0.9 pF, 1 MΩ, including many accessories)
HZO40
Active differential probe 200 MHz (10:1, 3,5pF, 1 MΩ)
HZO41
Active differential probe 800 MHz (10:1, 1pF, 200 kΩ)
HZO50
AC/DC current probe 30 A, DC to 100 kHz
HZO51
AC/DC current probe 100/1,000 A, DC to 20 kHz
HZ350
400 MHz passive probe
(for 400/300 MHz oscilloscopes)
HZ355
500 MHz passive probe
(for 500 MHz oscilloscopes)
Aging
±5 ppm/year
Refresh operating modes
1 ns/div. to 20 ms/div.
Roll operating modes
50 ms/div. to 50 s/div.
Deskew:
-62,5 ns to +61,5 ns
Step size
500 ps
Search functions:
Slope, Pulse, Peak, Rise-/Falltime, Runt
Marker:
up to 8 user definable marker for easy naviga-
tion; automatic marker function based on
search criteria
Digital Storage
Sampling rate:
2 x 2 GSa/s, 1 x 4 GSa/s
[4 x 2 GSa/s, 2 x 4 GSa/s]
Logic channels: 16 x 1 GSa/s
Resolution (vertical):
8 Bit, HiRes 10 Bit
Memory:
2 x 4 MPts [4 x 4 MPts], 1x 8 MPts [2 x 8 MPts]
Operation modes:
Refresh, Average (1024), Envelope, Peak-
Detect (500ps), Filter, Rol (free run/triggered
from time base 50 ms/div. and slower),
HiRes
Interpolation:
CH 1 to CH 4: Sinx/x, Pulse, Linear;
LC0 to 15: Pulse
Persistence:
Off, 50 ms to ∞
Delay pretrigger:
0 to 4 Million x (1/samplerate), Interlaced x2
posttrigger
0 to 8,59 Billion x (1/samplerate)
Display refresh rate:
Up to 4,800 waveforms/s
Display:
Dots, vectors (interpolation), ‘persistence’
Operation/Measuring/Interfaces
Operation:
Menu-driven (multilingual), Autoset,
help functions (multilingual)
Frequency counter:
0.5 Hz to 300/400/500 MHz
6 Digit resolution
Accuracy
15 ppm
Aging
±5 ppm/year
Auto measurements:
V
pp
, V
p+
, V
p-
, V
rms
, V
avg
, V
top
, V
base
, amplitude,
phase, frequency, period, risetime 80 / 90 %,
falltime 80 / 90 %, pos./neg. pulse width, pos./
neg. duty cycle, standard deviation, delay,
pos./neg. edge count, pos./neg. pulse count,
trigger period, trigger frequency
Statistic
Min., max., mean, standard deviation,
number of measurements for up to
6 Functions simultaneously
Cursor measurements:
∆V, ∆t, 1/∆t (f), V to GND, Vt related to Trigger
point, ratio X and Y, pulse count, edge count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation, rise time,
duty cycle
Application memory:
8 MByte for references, device settings and
formulars
Interface:
Internal
2x USB-Host (type A) (1x front side, 1x rear
side), mass storage (FAT16/32)
Exchangeable
HO730 Dual-Interface Ethernet/USB-Device
(type B)
Video OUT:
DVI-D (480 p, 60 Hz) for external display,
HDMI compatible
Trigger OUT:
BNC (rear side), Modes: Trigger, Mask
Optional:
USB-Device/RS-232 Dual-Interface (HO720),
IEEE-488 (GPIB) (HO740)
Mathematic functions
Quickmath:
ADD, SUB, MUL, DIV
Editor for formula sets:
Max. 5 formulas per formula set
Label for:
Math. memories and formula set
Sources:
All channels and math. Memories,
constants
Targets:
Math. memories
Functions:
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV, SQR, MIN, MAX, LOG
10
, LN,
Integral, Differential, High-pass filter,
Low-pass filter
Display:
Up to 4 math. memories with label
Mask test:
Signal test (pass/fail) based on previously
defined mask
Quickview:
Display of V
p+
, V
p-
, RMS value, rise time,
fall time
General Information
Probe ADJ Output:
1 kHz/1MHz square wave signal
approx. 0,2V
pp
(ta <4 ns)
Bus Signal Source (4Bit):
SPI, I
2
C, UART, retangle, 4Bit counter,
4 Bit random pattern
Internal RTC (Realtime clock):
Date and time for stored data
Line voltage:
100 V to 240 V, AC 50 Hz to 60 Hz, CAT II
Power consumption:
Max. 70 [90] W
Protective system:
Safety class I (EN61010-1), CSA (pending)
Operating temperature:
+5 °C to +40 °C
Storage temperature:
-20 °C to +70 °C
Rel. humidity:
5 % to 80 % (non condensing)
Theft protection:
Kensington Lock
Dimensions (W x H x D):
285 x 175 x 220 mm
Weight:
3.6 kg
All data valid at 23°C after 30 minute warm-up.
Recommended Accessories
HO720
USB-device/RS-232 dual-
interface card
HZ99
Carrying case for
protection and transport
HZO20
High voltage probe 1000:1
(400 MHz, 1000 V
rms
)
HZO30
1 GHz active probe
(0.9 pF, 1 MΩ, including many accessories)
HZO40
Active differential probe
200 MHz (10:1, 3.5 pF, 1 MΩ)
HZO41
Active differential probe
800 MHz (10:1, 1 pF, 200 kΩ)
HZO50
AC/DC current probe 30 A,
DC to 100 kHz
HZO51
AC/DC current probe
100/1000 A, DC to 20 kHz
HZ115
Active differential
high voltage probe
HZ355
500 MHz passive probe 10:1
with automatic identification
HZ355DU
Upgrade from
2 x HZ350 to 2 x HZ355,
only available when
purchasing a HMO3000
(300 MHz / 400 MHz
models)
HO740
IEEE-488 (GPIB) interface
card, galvanically isolated
HZ46
4 RU 19” rackmount kit
Accessories