          I m p o r t a n t   h i n t s

The warranty standards applicable are those of 
the country in which the instrument was sold. 
Reclamations should be directed to the dealer.

Only valid in EU countries

In order to speed reclamations customers in EU 
countries may also contact HAMEG directly. Also, 
after the warranty expired, the HAMEG service will 
be at your disposal for any repairs.

Return material authorization (RMA):

Prior to returning an instrument to HAMEG ask 
for a RMA number either by internet (http://www.
hameg.com) or fax. If you do not have an original 
shipping carton, you may obtain one by calling 
the HAMEG sales dept (+49-6182-800-300) or by 
sending an email to [email protected]

Maintenance

The most important characteristics of the instru-
ments should be periodically checked according to 
the instructions provided in the sections “Opera-
tional check and “Alignment procedcure. To obtain 
the normal operating temperature, the mainframe 
with inserted module should be turned on at least 
60 minutes before starting the test. The specifi ed 
alignment procedure should be strictly observed. 
When removing the case detach mains/line cord 
and any other connected cables from case of the 
mainframe HM8001-2. Remove both screws on 
rear panel and, holding case fi rmly in place, pull 
chassis forward out of case. When later replacing 
the  case,  care  should  be  taken  to  ensure  that 
it properly fi ts under the edges of the front and 
rear frames. After removal of the two screws at 
the rear of the module, both chassis covers can 
be lifted. When reclosing the module, care should 
be taken that the guides engage correctly with the 
front chassis.

Operation of the module

Provided that all hints given in the operating 
instructions of the HM8001-2 Mainframe were 
followed  especially for the selection of the cor-
rect mains voltage  start of operation consists 
practically of inserting the module into the right 
or left opening of the mainframe. The following 
pre-cautions should be observed:

Before exchanging the module, the mainframe 
must be switched off. A small circle (o) is now 
revealed on the red power button in the front 
centre of the mainframe.

If the BNC sockets at the rear panel of the 
HM8001-2 unit were in use before, the BNC cables 
should be disconnected from the basic unit for 
safety reasons. Slide in the new module until the 
end position is reached.

Before being locked in place, the cabinet of the 
instrument is not connected to the protective earth 
terminal (banana plug above the mainframe mul-
tipoint connector). In this case, no test signal must 
be applied to the input terminals of the module.

Generally, the HM8001-2 set must be turned on 
and in full operating condition, before applying any 
test signal. If a failure of the measuring equipment 
is detected, no further measurements should 
be performed. Before switching off the unit or 
exchanging a module, the instrument must be 
disconnected from the test circuit.

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 

Summary of Contents for HM8021-4

Page 1: ...r s a l C o u n t e r H M 8 0 2 1 4 Handbuch Manual Manuel Manual Deutsch English Fran ais Espa ol 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www Tes...

Page 2: ...cable HZ72 from HAMEG is suitable 2 Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible Without instruction in the manual fo...

Page 3: ...rmation regarding CE marking 14 Universal Counter HM8021 4 16 Speci cations 17 Important hints 18 Safety 18 Used Symbols 18 Operating conditions 18 Warranty and repair 18 Maintenance 19 Operation of t...

Page 4: ...put A Input impedance 1 M maximum sensitivity 20mVrms Input C Input impedance 50 maximum sensitivity 30mVrms Time interval resolution up to 10 ps Offset mode over the entire measurement range Gate inp...

Page 5: ...ty normal triggering DC 80 MHz 20 mVrms sine wave 80 mV pulse 80 MHz 150 MHz 60 mVrms sine wave 20 Hz 80MHz auto trig 50 mVrms sine wave Minimum pulse width 5ns Input noise 100 V typ Coupling AC or DC...

Page 6: ...t or discon nection of the protective earth terminal is likely to render the instrument dangerous Intentional interruption is prohibited The istrument must be disconnected and secured against unintent...

Page 7: ...d rear frames After removal of the two screws at the rear of the module both chassis covers can be lifted When reclosing the module care should be taken that the guides engage correctly with the front...

Page 8: ...ng will restart when Display Hold is switched off Display Hold starts and stops counting in the TOTALIZE function mode Function indicators LEDs Refer to Measuring functions Function pushbuttons The le...

Page 9: ...led by an external source Triggering measuring and counting Power on test A practical test of the correct operation of the HM8021 4 is run automatically at power on As soon as power is applied the dis...

Page 10: ...r level setting The input signal is triggered from 50mV up to the maximum input voltage of 5V The input frequency for the C input must always be in the range from 100MHz to 1000MHz For frequencies low...

Page 11: ...ate time of 10sec Period measurement For measurement of the period duration the re ciprocal value of the frequency T 1 f is measured in seconds The signal is applied as for frequency measurement Time...

Page 12: ...and DISPLAY HOLD should be in OFF position 2 Apply a frequency standard of 1 5 or 10MHz to input A and adjust channel A trigger setting for a stable reading 3 Depress RESET and then GATE TIME for appr...

Page 13: ...the counter has recognized a 10MHz standard During the following 45 seconds the signal is measured and the HM8021 4 is recalibrated Finally the new calibrated unit automatically switches back to norm...