Operating conditions

The permissible ambient temperature range for operation is +10°C
...+40°C. During storage and transportation the temperature may be in
the range of -40°C...+70°C. In case of condensation buildup during
transport or storage the instrument may not be set in operation before
two hours of acclimatization. The instrument is intended to be used in
a clean and dry environment. It may not be operated in a heavily dust
laden, moist or explosive atmosphere or aggressive chemical effects.
There are no limitations for the operating position. A sufficient free air
circulation (cooling by convection) has to be kept for the instrument.

Warranty and repair

HAMEG instruments are subject to a strict quality control. All instruments
are burned in for 10 hrs prior to shipment. By intermittent operation
almost all early failures are detected. After burn-in a thorough test of
all functions and of quality is run, all specifications and operating
modes are checked.

In case of reclamations during the two years warranty period please
contact the dealer from whom you purchased your HAMEG instrument.
Customers from the Federal Republic of Germany may directly contact
HAMEG for warranty processing in order to speed up the procedure.

The proceeding of repairs during the warranty period is subject to our terms
of warranty which are available on our web-site 

http://www.hameg.com

Even after expiry of the warranty period please do not hesitate to
contact our HAMEG customer service for repairs and spare parts.

Return Material Authorization (RMA):

Before sending back your instrument to HAMEG do apply for a RMA
number either by fax or on the Internet: http://www.hameg.de.
If you do not have suitable packaging for the instrument on hand please
contact the HAMAG sales department (Tel.: +49 (0) 6182/800 300,
E-mail: [email protected]) to order an empty original cardboard box.

Summary of Contents for HM6050-2

Page 1: ...d a n c e S t a b i l i z a t i o n N e t w o r k H M 6 0 5 0 2 Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Hameg H...

Page 2: ...50 2 20 Specifications 21 Operating Manual 22 Introduction 22 Used Symbols 22 Operation according to rules 22 Safety 22 Replacement of fuses 23 Operating conditions 24 Warranty and repair 24 Operating...

Page 3: ...uction in the manual for a reduced cable length the maximum cable length of a dataline must be less than 3 meters If an interface has several connectors only one connector must have a connection to a...

Page 4: ...WG EMC Directive 89 336 EEC amended by 91 263 EWG 92 31 EEC Directive EMC 89 336 CEE amend e par 91 263 EWG 92 31 CEE Directriz EMC 89 336 CEE enmendada por 91 263 CE 92 91 CEE Niederspannungsrichtlin...

Page 5: ...tly to the LISN Inside the LISN the power lines are terminated with a well defined impedance network against each other and against ground The HM6050 2 Line Impedance Sta bilization Network LISN in pr...

Page 6: ...output with PE Test signal output 50 BNC jack Test Receiver Rear panel Power line cable 3 x 1 5 mm2 male with PE Ground Alu Block with tread 4 mm 40 x 20 x 20 mm RS 232 Interface 9 pin Sub D female Tr...

Page 7: ...ns It conforms to the regulations as defined in CISPR Publ 16 or EN55011 Safety This instrument has been designed and tested in accordance with VDE 0411 Part 1 Safety requirements for electrical equip...

Page 8: ...M6050 2 contains a fuse Ex factory the HM6050 2 is set to 230V 10 50 60Hz If the instrument shall operate at a mains voltage of 115 V 10 the wire bridges have to be changed by soldering Insert or repl...

Page 9: ...ly failures are detected After burn in a thorough test of all functions and of quality is run all specifications and operating modes are checked In case of reclamations during the two years warranty p...

Page 10: ...nd connection according to Class 1 2 Ground jack This jack is used for testing DUTs which don t have a protective ground line in their AC power cable but do have a separate ground connection The DUT s...

Page 11: ...tached Test Receiver s or Spectrum Analyzer s input circuitry from high transient voltages After pushing button 10 the transient limiter circuit will be bypassed A blinking red LED 12 indicates this o...

Page 12: ...onnected between the ground block and the chamber s shielding material VDE 0877 Part1 16 RS 232 interface Safety hints Attention All interface lines are galvanic coupled to the LISN As mentioned in pa...

Page 13: ...upper case letters Command Function Indication R Remote control enabled RM LED lit O Local control RM LED dark P Protect ground line sim circuit on PE LED lit p Protect ground line sim circuit off byp...

Page 14: ...hich may be touched by the user lie on a dangerous high voltage level EMC measurement procedures for LISN HM6050 2 Measurements have to be performed according to the VDE regulations VDE 0877 Part 1 Af...

Reviews: