Hameg HM 8012 Service Manual Download Page 2

2

Subject to change without notice

General information regarding the CE marking

HAMEG instruments ful

fi

 ll the regulations of the EMC directive. The 

conformity test made by HAMEG is based on the actual generic- and 
product standards. In cases where different limit values are applicable, 
HAMEG applies the severer standard. For emission the limits for 
residential, commercial and light industry are applied. Regarding the 
immunity (susceptibility) the limits for industrial environment have 
been used.

The measuring- and data lines of the instrument have much in

fl

 uence 

on emmission and immunity and therefore on meeting the acceptance 
limits. For different applications the lines and/or cables used may 
be different. For measurement operation the following hints and 
conditions regarding emission and immunity should be observed:

1. Data cables
For the connection between instruments resp. their interfaces and 
external devices, (computer, printer etc.) suf

fi

 ciently screened cables 

must be used. Without a special instruction in the manual for a reduced 
cable length, the maximum cable length of a dataline must be less than 
3 meters and not be used outside buildings. If an interface has several 
connectors only one connector must have a connection to a cable.
Basically interconnections must have a double screening. For IEEE-bus 
purposes the double screened cables HZ72S and HZ72L from HAMEG 
are suitable.

2. Signal cables
Basically test leads for signal interconnection between test point and 
instrument should be as short as possible. Without instruction in the 
manual for a shorter length, signal lines must be less than 3 meters 
and not be used outside buildings.
Signal lines must screened (coaxial cable - RG58/U). A proper ground 
connection is required. In combination with signal generators double 
screened cables (RG223/U, RG214/U) must be used.

3. In

fl

 uence on measuring instruments.

Under the presence of strong high frequency electric or magnetic 

fi

 elds, 

even with careful setup of the measuring equipment an in

fl

 uence of 

such signals is unavoidable.
This will not cause damage or put the instrument out of operation. Small 
deviations of the measuring value (reading) exceeding the instruments 
speci

fi

 cations may result from such conditions in individual cases.

HAMEG Instruments GmbH

Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt
The HAMEG Instruments GmbH herewith declares conformity of the product 
HAMEG Instruments GmbH déclare la conformite du produit

Bezeichnung / Product name / Designation: 
 

 

 

Multimeter / Multimeter /

  

 

Multimètre

Typ / Type / Type: 

 

HM8012

mit / with / avec:     

Optionen / Options / Options:   

mit den folgenden Bestimmungen / with applicable regulations / avec les directives 
suivantes

 

EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG

 

EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC

 

Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE

Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE

Angewendete harmonisierte Normen / Harmonized standards applied / Normes 
harmonisées utilisées

Sicherheit / Safety / Sécurité
EN 61010-1:2001 (IEC 61010-1:2001)
Überspannungskategorie / Overvoltage category / Catégorie de surtension: II

Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2
Elektromagnetische Verträglichkeit / Electromagnetic compatibility / 
Compatibilité électromagnétique

 Hersteller 

HAMEG 

Instruments 

GmbH 

KONFORMITÄTSERKLÄRUNG 

 

 

Manufacturer 

Industriestraße 6 

DECLARATION OF CONFORMITY 

 

Fabricant 

D-63533 Mainhausen 

DECLARATION DE CONFORMITE

EN 61326-1/A1 Störaussendung / Radiation / Emission: 
Tabelle / table / tableau 4; Klasse / Class / Classe B.

Störfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1. 

EN 61000-3-2/A14 Oberschwingungsströme / Harmonic current emissions / Émissions 
de courant harmonique: Klasse / Class / Classe D.

EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / 
Fluctuations de tension et du fl icker.

Datum /Date /Date                                          
22.07.2004
 

 

 

Unterschrift / Signature /Signatur 

  

 

 

G. 

Hübenett

  

 

 

Produktmanager

G e n e r a l   i n f o r m a t i o n   r e g a r d i n g   t h e   C E   m a r k i n g          

Summary of Contents for HM 8012

Page 1: ...Service Manual 4 D i g i t M u l t i m e t e r H M 8 0 1 2...

Page 2: ...g equipment an influence of such signals is unavoidable This will not cause damage or put the instrument out of operation Small deviations of the measuring value reading exceeding the instruments spec...

Page 3: ...tice C o n t e n t Declaration of Conformity 2 General information regarding the CE marking 2 4 Digit Programmable Multimeter HM8012 4 Specifications 5 Control elements 6 Function test 7 Calibration 8...

Page 4: ...10 m 0 1 C F Offset function relative value measurement in basic measurement functions Input impedance 1 G 0 5 V and 5 V DC range RS 232 interface PC software for control and data logging Mainframe H...

Page 5: ...1 A 10 A 1 mA Accuracy 0 5 500 mA 0 7 of reading 0 07 of f s 40Hz 5kHz 10 A 1 of reading 0 07 of full scale AC DC measurements As shown for AC 25 digits Resistance Measurement ranges 500 5 k 50 k 500...

Page 6: ...connector for all the measurement functions to which the potential close to the ground of the measured quantity will be applied For safety reasons the voltage across this ter minal compared to the ca...

Page 7: ...ange is left to user initiative using the keys and Unit display zone LED This zone contains a display of the measurement units It al so identifies the function selected by pressing the or key AC DC pu...

Page 8: ...yet corrected value will be displayed The LED will be on 3 Press AUTO to perform the calibration the corrected value should be displayed 4 Press in order to proceed Pressing will dis play the actual c...

Page 9: ...9 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 10: ...10 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 11: ...11 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 12: ...12 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 13: ...13 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 14: ...14 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 15: ...15 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 16: ...16 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 17: ...17 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 18: ...18 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 19: ...19 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 20: ...20 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 21: ...21 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 22: ...22 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 23: ...23 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 24: ...24 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 25: ...25 Subject to change without notice C i r c u i t a n d l a y o u t d i a g r a m s...

Page 26: ...26 Subject to change without notice N o t e s...

Page 27: ...27 Subject to change without notice N o t e s...

Page 28: ...ents 8100 Series Subject to change without notice 4S 8012 00E0 02 11 2005 gw HAMEG Instruments GmbH HAMEG Instruments GmbH Industriestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trade...

Reviews: