C9300-124 Ver.1.4
39
14-3-2 TIMING I/O CONNECTOR PIN ASSIGNMENTS [TIMING I/O]
The camera uses HIROSE model HR10A-7R-6S connector for inputting the external trigger
pulse when the camera is operated in external control mode. Input should be TTL level, and the
external trigger pulse polarity can be set either to negative or positive.
No. Signal
Pin
connections
1 Ext.Trigger
2 Digital
GND
3 SG
output
4 Digital
GND
5 NC
6 Digital
GND
HR10A-7R-6S
•
Do not connect anything to pins 5 and 6.
14-3-3 CAMERA CONNECTOR PIN ASSIGN MENT [POWER]
The camera employs HIROSE mode HR10A-10R-12PB connectors.
No. Signal
Pin connections
1 GND
(Camera)
2
12 V (Camera)
3 NC
4 NC
5 NC
6 NC
7 NC
8 NC
9 NC
10 GND
(Peltier)
11
12 V (Peltier)
12 NC
HR10A-10R-12PB
Summary of Contents for C9300-124
Page 42: ...C9300 124 Ver 1 4 41 15 DIMENSIONAL OUTLINES 15 1 CAMERA Unit mm Depth 8 F mount Depth 8 ...
Page 45: ...C9300 124 Ver 1 4 44 Technical sheet 1 C9300 124 Dimensional outline with Camera mount ...
Page 46: ...C9300 124 Ver 1 4 45 Technical sheet 2 C9300 124 Dimensional outline without Camera mount ...