USAGE
TECHNICAL SPECIFICATIONS
Environmental conditions
for the device
0.1
°C /
± 0.5
°C
Temperature Sensors
2x DS18B20 one wire
Measurement range
-50
°C
με
100
°C
Step / Accuracy
3
2
To use the device, visit our web app at
https://hamsystems.eu
or search
HAM Systems
at the App Store / Play Store
The
Setup button
is used during the setup process to pair the device to your Wi-Fi network
The
Restart button
restarts the device, similar to power cycling
View real time temperature readings
View historical temperature readings in detail
Create interactions between other HAM Systems devices by using IF this THEN that style
rules
Notifications via app, email, SMS or cloud phone call
Organization of devices into groups and floorplans
Encrypted communications via TLS
Generate PDF / CSV reports
Device sharing with other users
Some features of the app:
SETUP
Connect the device according to the wiring diagram
on the first page
Check your connections
and
power up the device
either via micro-USB or from
terminals
Open the HAM Systems app
. If you don't have an account create one
Click on (+) button
on the devices list view on the smartphone app
Follow the instructions
on the app
After completing the instructions, check that the green LED is fully on
If the Status LED is fully on and the device does not appear on the app, then you may also
need
claim the device
to your account. Click on (+) and select the Claim Device option
You should now be able to
view the real-time readings of the device on the app
1.
2.
3.
4.
5.
6.
7.
8.
In order to connect the device to your Wi-Fi network, you need to use the HAM Systems app. All the other
features are also available on the Web on https://hamsystems.eu
If you want to change the Wi-Fi network of your device
, you can do so by doing
the steps 3-5 . You
don't have to re-claim
your device in this case.
SAFETY WARNINGS
In case you are having difficulties, you can
try restarting the device
and repeating the
steps.
Incorrect wiring of the device may lead to
permanent damage to the device and / or
sensors. Make sure your connections are
correct before powering the device.
Do not disassemble the device.
Doing so, voids the warranty.
In case of loss of network, you will
ΝΟΤ
be
able to monitor the real-time values of the
device.
You should not rely on the device in
such a way that puts human or animal
lives at risk.
You are responsible for checking the
accuracy of the readings periodically.
-10
°C με
55
°C (5V), -
10
με
40
°C (12V)
5% - 90 % RH
General inputs
Power supply
Communications protocol
Up to
2
5-12
VDC,
0.5
A
Wi-Fi
IEEE 802.11 b/g/n
2.4Ghz
Device Dimensions/Material
External Sensor
55
mm
x
44.1
mm
x
21.5
mm, ABS-V0