TROUBLESHOOTING

 

The green LED does not turn on and 
the device is reported as disconnected 
on the internet platform

 

If the green LED is not lit, then the 
device may be unable to be connected 
to the Internet Platform.

 

 

• 

Check your internet connection. If 
you don

t seem to be able to access 

the internet through the Wi

-

Fi router 

then contact your Internet Service 
Provider (ISP).

 

• 

Check that the server is accessible at 
https://hamsystems.eu or open the 
smartphone app. If you are unable to 
access the server, try again after 5 
minutes.

 

• 

Try to reset the device by using the 
reset button and wait a few seconds. 
Repeat a few times.

 

• 

Check that the device is connected to 
your Wi

-

Fi router. A way this can be 

achieved is by accessing the router

configuration page. If none of the 
above suggestions worked, then 
repeat the steps 2

-

5 of the setup 

instructions.

 

The temperature measurement is way 
off

 

• 

Check that you have connected the 
PT

-

100 probe correctly and that 

there is a good connection between 
the wires and the terminals

 

• 

Check that the PT

-

100 probe is not 

damaged or cut.

 

• 

Check that your device is connected 
and the connected status LED is fully 
lit.

 

No dry contact reading

 

• 

Check your dry contact connections.

 

• 

Check that the wires used are not cut 
at any point.

 

• 

Check that your device is connected 
and the connected status LED is fully 
lit

 

• 

You may need to cycle the dry con-
tact once for it to appear on the app/
website

 

More in

-

depth documentation, help, declarations of conformity, instructions for the 

Internet platform, Terms and Conditions, Privacy policy and more are available at 

https://hamsystems.eu

 

Summary of Contents for ThermoSense

Page 1: ...y through micro USB cable or DC power supply unit RESET and SETUP button Easy installation Up to 2 dry contact inputs for door sensing and more Warranty 2 years 1 P1 probe wire 2 P1 probe wire same color as 1 3 P2 probe wire 4 NC 5 V power supply alternative to micro USB 6 G1 dry contact 1 7 G2 dry contact 2 8 GND dry contact common supply ground negative 9 RESET 10 SETUP 11 Connection Status LED ...

Page 2: ...f the previous steps were successful and the device is connected to the internet then you will be redirected to the a screen where you can monitor your device In case there is an issues on the steps 2 4 5 try pushing the Reset button and wait a few seconds SETUP INSTRUCTIONS SAFETY WARNINGS In case you didn t connect the device correctly it may be damaged or destroyed Recheck your connections befo...

Page 3: ...the desired range via SMS e mail phonecalls and push notifications Create interactions between devices in an If This Then Than IFTTT format Share device usage with other users Secured communications with TLS Organize devices in groups and floor plans USAGE TECHNICAL SPECIFICATIONS Sensors Pt100 3 wire for external temperature measurement Internal for temperature and humidity measurement Resolution...

Page 4: ...chieved is by accessing the router s configuration page If none of the above suggestions worked then repeat the steps 2 5 of the setup instructions The temperature measurement is way off Check that you have connected the PT 100 probe correctly and that there is a good connection between the wires and the terminals Check that the PT 100 probe is not damaged or cut Check that your device is connecte...

Reviews: