Hold the magnet switch tool against the sensor until the LED
indicator starts to blink brightly for one minute. When the LED goes off,
the sensor is switched on.
Detection capability
• Operational temperature range -20 ºC to + 50 ºC.
Storage temperature range 0º C to +20 ºC.
Usage prohibited in moisture condensing/freezing
environments.
Accuracy ±0,3 ºC.
• Accelerometer reports orientation or vibrations count in machine
usage monitoring mode from 128mG - 8G (default values) and can
be configured to high movement mode from 128mG -16G.
• Magneto-resistive sensor. Detects the presence of a magnetic
field from a magnet or high DC current.