10
TMS-4 receiver
Size (without connector)
103.80 x 80.70 x 36.80mm
Operating Voltage
12V to 32V DC
Ambient Operating Current
50mA
Receiver frequency
433.92MHz + / - 50KHz
Ingress Protection
IP67
Operating Temperature
-40
°
C to +85
°
C (-40
°
F to 185
°
F)
Configuration
via Haltech NSP or ESP Software
CAN Connection
6-position TE MCON Connector
TMS-4 Internal Sensors (HT-011600)
Battery Model
CR2023, 380mAh (Not Replaceable)
Battery lifespan
Up to 3 years
Standby Current
<0.7uA
Pressure Measurement Range
0-800kpa (0-116psi)
Temperature Measurement Range
-40
°
C to +125
°
C (-40
°
F to 257
°
F)
Ingress Protection
IP67
TMS-4 External Sensors (HT-011601)
Battery Model
CR1632, 140mAh (Replaceable)
Battery Lifespan
1-2 years
Standby Current
<0.7uA
Pressure Measurement Range
0-800kpa (0-116psi)
Temperature Measurement Range
-40
°
C to +125
°
C (-40
°
F to 257
°
F)
Ingress Protection
IP69
TMS-4 SPECIFICATIONS
Summary of Contents for TMS-4
Page 1: ...1 TMS 4 QUICK START GUIDE ...