Instruction Manual PSx3xxPN
16
Name
Par.
Number
Function
Type/
Range
Back
up
Delivery
State
R/W
Parameter group “others” (continued)
configuration
for
connection
timeout
93
Bits 1-0: configuration for connection
timeout (if a connection has been
established and lost)
0x00: continue moving (drive will continue
moving to the actual target position)
0x01: drive will abort any positioning
0x02: drive will move to a save position
which is defined by Par. 94
0x03: reserved
Bits 3-2: configuration of save position run
when no connection is being established
after a certain time at power-up
0x00: no save position run at power-up
0x01: save position run after 15 sec
0x02: save position run after 30 sec
0x03: save position run after 60 sec
16 bit
yes
1
R/W
save position
for
connection
timeout
94
drive will move to this position if
-
a connection loss has been
detected and bits 1-0 of Par. 93
are set to 0x02
-
no connection is being established
after a certain time at power-up
and bits 3-2 are being set
appropriate
31 bit
yes
0
R/W
repetition
time for save
position run
95
drive will start another save position run if
the last save position run was not
successful (e.g. because of undervoltage,
positioning error (block) or
overtemperature)
value in sec; 0
no repetition
16 bit
yes
0
R/W