background image

 

PS18 Instruction Manual 

 

Purpose of instruction manual 

 

This instruction manual describes the features of the PS18 differential pressure 
transducer and provides guidelines for its use. 
 
Improper use of this instrument or failure to follow these instructions may cause injury 
or equipment damage. All individuals responsible for operating this instrument must 
therefore be properly trained and aware of the hazards, and must carefully follow 
these operating instructions and the safety precautions detailed within. 

Contact the 

manufacturer if you do not understand any part of this instruction manual.

 

 
Handle this manual with care: 

  It must be readily available throughout the lifecycle of the instrument. 

  It must be provided to any individuals who assume responsibility for operating the 

instrument at a later date. 

  It must include any supplementary materials provided by the manufacturer. 

 
The manufacturer reserves the right to continue developing this instrument model 
without documenting such development in each individual case. The manufacturer 
will be happy to determine whether this manual is up-to-date.

 

 

Conformity

 

 
This instrument corresponds to the state of the art and meets all legal requirements 
set forth in EC directives as evidenced by the CE label.

 

 
 
 

© 2005

 

 
The manufacturer owns the copyright to this instruction manual. This manual contains 
data, instructions and drawings pertaining to the features and usage of this 
instrument; copying this manual in part or in full or distributing it to third parties is 
prohibited.

 

 

Summary of Contents for PS 18

Page 1: ...Pressure Transducer halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup walcher com Internet www halstrup walcher com Doc...

Page 2: ...pping assembly electrical connections and start up 4 1 3 Troubleshooting maintenance repairs disposal 4 1 4 Symbols 5 2 Instrument description 6 3 Start up 6 3 1 Features 6 3 2 Instrument connections...

Page 3: ...ghout the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials provided...

Page 4: ...ned and authorized by the operator of the facility may assemble the instrument and set up its electrical connections The instrument may only be operated by appropriately trained individuals who have b...

Page 5: ...ymbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards WARNING This warns you of a potential hazard that could lead to b...

Page 6: ...flection without contacting the membrane The instrument has no frictional parts or parts subject to mechanical wear 3 Start up 3 1 Features Although the PS 18 pressure transducer is highly robust it i...

Page 7: ...for a short period Signal U 24V GND B 99 30 8 2 2x 4 5 88 5 67 5 45 1 68 halstrup wa cher Model PS 18 Terminal ST3 Assignment Pin 3 24 VAC or 24 VDC Pin 2 24 VAC or GND ground Pin 1 output signal 0 10...

Page 8: ...t be set when the ports are open this value is dependent upon the output signal measurement range 0 10 V 0 20 mA 4 20 mA zero point 0 00 V 0 00 mA 4 00 mA 5 Troubleshooting Error description Potential...

Page 9: ...on request deviation from characteristic curve setting limiting value typically 2 5 temperature dependent drift in zero point 0 1 K within the 10 C 50 C range temperature dependent drift in measuremen...

Page 10: ...lectrical connection screw terminals for cables up to 2 5 mm2 mounting orientation vertical if horizontal use potentiometer 0 to reset dimensions w x h x d 99 x 32 8 x 88 5 mm protection class IP20 we...

Page 11: ...PS18 Instruction Manual 11 7 Dimension drawings Signal U 24V GND B 99 30 8 2 2x 4 5 88 5 67 5 45 1 68 halstrup wa cher 7100003814_PS18_eng doc 01 02 2018 Ht Su Ze Terminals...

Reviews: