P82R Instruction Manual

 

 

 

Purpose of instruction manual 

 

This instruction manual describes the features of the P82R differential pressure 
transducer and provides guidelines for its use. 
 
Improper use of this instrument or failure to follow these instructions may cause injury 
or equipment damage. Every person who uses the device must therefore read the 
manual and understand the possible risks. The instruction manual, and in particular 
the safety precautions contained therein, must be followed carefully. 

Contact the 

manufacturer if you do not understand any part of this instruction manual.

 

 
Handle this manual with care: 

  It must be readily available throughout the lifecycle of the instrument. 

  It must be provided to any individuals who assume responsibility for operating the 

instrument at a later date. 

  It must include any supplementary materials provided by the manufacturer. 

 
The manufacturer reserves the right to continue developing this instrument model 
without documenting such development in each individual case. The manufacturer 
will be happy to determine whether this manual is up-to-date.

 

 

Conformity

 

 
This instrument corresponds to the state of the art and meets all legal requirements 
set forth in EC directives as evidenced by the CE label.

 

 
 
 

© 2005

 

 
The manufacturer owns the copyright to this instruction manual. This manual contains 
data, instructions and drawings pertaining to the features and usage of this 
instrument; copying this manual in part or in full or distributing it to third parties is 
prohibited.

 

 

Summary of Contents for P82R

Page 1: ...Root Extracted Characteristic Curve halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup walcher com Internet www...

Page 2: ...connections and start up 4 1 3 Troubleshooting maintenance repairs disposal 4 1 4 Symbols 5 2 Instrument description 6 3 Start up 6 3 1 Features 6 3 2 Instrument connections 7 3 3 Output signals 8 4 C...

Page 3: ...t the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials provided by...

Page 4: ...ained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections The instrument may only be operated by appropriately trained individuals who have...

Page 5: ...ymbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards WARNING This warns you of a potential hazard that could lead to b...

Page 6: ...g the instrument in the direct vicinity of any sources of radiation or heat such as heaters as this could result in measurement errors Ideally the instrument should be mounted vertically on a wall not...

Page 7: ...ent connections Fig 1 not all components are shown Terminal Analog output 1 2 0 10 V ground GND 3 4 0 20 mA 4 20 mA ground GND Terminal Supply voltage 11 13 24 115 230 VAC 50 60 Hz 24 115 230 VAC 50 6...

Page 8: ...everse polarity Connecting the supply voltage to the outputs will destroy the transducer 3 3 Output signals voltage output 0 10 V lin rad U V U 10 U 10 V Urad Ulin 0 V 100 p current output 0 20 mA cur...

Page 9: ...ansducer is not connected to a source of pressure This may require having to disconnect the tubing from the pressure ports After calibrating the zero point slide the S1 switch back to root extracted 5...

Page 10: ...n the P5 trimmer to the left until the output signal 0 V 0 4 mA output signal incorrect defective output protection diode defective pressure measurement cell for current output output loadtoo high for...

Page 11: ...dium air all non aggressive gases nominal temperature 10 C to 50 C operating temperature 0 C to 60 C storage temperature 10 C to 70 C relative humidity 0 80 EMC standards EN 50081 part 1 and EN 50082...

Page 12: ...icate output signal attenuation up to 5 s silicon free materials for parts in contact with medium Appendix A Parts in contact with measurement medium Beryllium bronze CuBe2 Araldite CY236 HY988 Mu met...

Page 13: ...P82R Instruction Manual 13 8 Dimension drawings 122 17 25 22 75 Option LCD 4 5 111 90 5 20 120 7100 0003244_P82R_eng doc 12 09 2005 ka Ze...

Reviews: