PAGE 2

97811C  (Rev. G - 09/17)

OVL - EBPFR/SBPFR/SEBPFR COOLER INSTALLATION

The freeze resistant package must be mounted on an interior wall in a heated area.  The room temperature of the interior heated 

area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted.  If recess mounted the 

surface of the cover must be flush with the interior wall surface.  The package is furnished with screws for mounting the cover to 

the box.  If the box is recess mounted, do not fasten the top and bottom of the cover to the box.  Use the holes on the front only.

1.  Fountains using the MPW Mounting Plate refer to Fig's. 7, 8, 9, or 10 for hanger bracket location and rough-in dimensions.  

     

NOTE:

 Review separate installation instructions for details of the MPW Mounting Plate.

     Fountains using the Wall Plate Assy. refer to Fig's. 1, 2, 3, 4, 5, or 6 for rough-in dimensions. 

2.  Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight for single fountain and

     300 lbs. for dual fountains). These dimensions are required for compliance with ANSI Standard A117.0.

3.  Installing back panel.

  Ftn. with MPW Mounting Plate: Refer to Fig. 15 for placement of braces onto back panel. Place the upper edge of the panel

  above hanger bracket. Slide the panel down until it engages the hanger bracket. Be sure back panel is firmly engaged 

  before releasing it. 

     Ftn. with Wall Plate Assy: Place the upper edge of the panel above mounting plate on the wall. Slide the panel down until it 

     engages the hanger. Be sure back panel is firmly engaged before releasing it.

4.  Remove bottom access panel from fountain basin and save the screws.

     Ftn. with MPW Mounting Plate: Install the fountain to the back panel and wall using (4) 5/16 “ x 6” long threaded rods,

     washers, and nuts (provided). Tighten securely.

     Ftn. with Wall Plate Assy: Install the fountain to the back panel and wall using (4) 5/16" x 3/4" long bolts and washers

     (provided) thru holes in back panel. A washer is used on the bottom two (2) holes only. Tighten securely.

5.  Assemble the operating cable to the fountain bracket. (Fountain should be mounted to exterior wall). The adjustment nuts

  should be in the middle of threaded area on the operating cable. See Figure 12. Create a loop in the cable and thread the 

  free end of the cable through the wall into the freeze resistant box. 

 

6.  Connect free end of operating cable to the valve-operating bracket in the freeze resistant box. Remove cable free play by 

 

  adjusting the jam nuts on the ends of the operating cable. See Figure 11. 

 

7.  Connect water line from fountain bubbler into freeze resistant box. The connection to the box uses a quick connect water  

  fitting.  Position the water line, in the fountain, to drain back into interior mounted box. Any water left standing, in the   

  exterior line, can freeze. See Fig. 18.  

             

             To insert tubing, push tube straight into fitting until it reaches a positive stop. To remove tubing from the fittings, relieve 

 

  water pressure, push in on dark gray collar while pulling out on the tubing. See Figure 17. 

 

8.  Connect drain and water supply lines to the freeze resistant fountain. Refer to Figure's 1 thru 10 for component positions

 

  Inline strainer must be used on the inlet water line. See Fig. 16.

 
 

Start-up

 

 

1.  Turn on building water supply and check all connections for leaks. Repair as required.

 

 

2.  Stream height is factory set at 35 PSI.  If stream height (See Fig. 19) needs to be changed adjust the regulator in the freeze  

            resistant package. Clockwise adjustment raises stream height, counter clockwise adjustment will lower stream.

 

3.  Adjust operating cable as required.  Cable system should have a minimal amount of free play to allow for proper valve

 

  operation. If the system is too tight the valve will stay in the on position creating constant water flow. Too much free play will

 

  result in non-operation of the valve with the push-buttons.  

 

4.  Note:  Water from the drain back tube in the freeze resistant package, will continue to run while the valve is actuated.

 

5.  After cable system is adjusted properly stuff flexible insulation into any openings between the outside wall and the interior box.  

 

6.  Recheck all connections. If all connections are leak free replace cover(s) on the freeze resistant box(es) and fountain(s).

Summary of Contents for OVLEBPFR

Page 1: ...interior heated wall The interior space must maintain a minimum temperature of 50 F 10 C Refer to the Freeze Resistant Package for the rough in dimensions for installation IMPORTANT ALL SERVICE TO BE...

Page 2: ...Tighten securely 5 Assemble the operating cable to the fountain bracket Fountain should be mounted to exterior wall The adjustment nuts should be in the middle of threaded area on the operating cable...

Page 3: ...PAGE 3 97811C Rev G 09 17 OVLEBPFR OVLSBPFR OVLSEBPFR FIG 1 FIG 2 TOP VIEW ROUGH IN FOR OVL SBPFR OVL EBP FR...

Page 4: ...mm 43 5 8 1108mm 6 152mm 16 406mm 5 1 4 133mm 5 1 4 133mm FINISHED FLOOR 8 203mm 1 2 13mm 1 25mm 3 8 DIA 10 10mm B A BACK PANEL WALL PLATE ASSEMBLY D 1 1 4 32mm C 2 X 3 1 2 SLOT FOR A B C STUDS REQUIR...

Page 5: ...mm 43 5 8 1108mm 1 25mm 1 2 13mm 5 1 4 133mm 5 1 4 133mm 8 203mm 8 203mm 1 1 4 32mm 6 152mm 16 406mm STUDS REQUIRED FOR FRAME WALL CONSTRUCTION BACK PANEL WALL PLATE ASSEMBLY A B C D 2 X 3 1 2 SLOT FO...

Page 6: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 6 97811C Rev G 09 17 12 305mm MAX WALL THICKNESS 7 1 4 184mm 7 1 4 184mm 12 1 8 308mm 12 1 8 308mm FIG 5 TOP VIEW ROUGH IN FOR OVL SEBPFR...

Page 7: ...8 67mm 3 5 8 92mm 12 305mm MAX WALL THICKNESS 14 1 4 362mm 15 5 16 389mm 19 3 16 488mm 20 1 4 514mm 21 5 16 541mm 25 3 16 640mm FINISHED FLOOR 28 11 16 728mm 34 11 16 880mm 25 3 4 654mm 28 11 16 728mm...

Page 8: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 8 97811C Rev G 09 17 7 1 4 184mm 12 1 8 307mm 12 305mm MAX WALL THICKNESS TOP VIEW ROUGH IN FOR OVL EBPFR WITH MPW100 MOUNTING PLATE FIG 7...

Page 9: ...VL EBPFR WITH MPW100 MOUNTING PLATE FIG 8 28 11 16 728mm 27 686mm ADA REQUIREMENT 7 1 16 180mm 43 7 8 1114mm 28 11 16 729mm 1 25mm 1 1 4 32mm 1 2 13mm 1 7 8 47mm 8 203mm 16 406mm 8 203mm MPW100 MTG PL...

Page 10: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 10 97811C Rev G 09 17 7 1 4 184mm 12 1 8 307mm 7 1 4 184mm 12 1 8 307mm 12 305mm MAX WALL THICKNESS TOP VIEW ROUGH IN FOR OVL SEBPFR WITH MPW200 MOUNTING PLATE FIG 9...

Page 11: ...8 454mm 28 11 16 728mm 33 838mm 14 1 4 362mm 13 1 4 337mm 17 3 4 451mm 34 11 16 881mm 20 1 4 515mm 23 3 4 604mm 27 686mm ADA REQUIREMENT 2 5 8 66mm 3 5 8 91mm MPW200 MTG PLT REF SEPARATE INSTALLATION...

Page 12: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 12 97811C Rev G 09 17 CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play FIG 11 FIG 12 FIG 13...

Page 13: ...ET NOTE WATER FLOW DIRECTION BUILDING WATER INLET 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY SERVICE STOP NOT FURNISHED FIG 14 FIG 17 FIG 16 SEE FIG 8 SEE FIG 13 Installing Back Panel When...

Page 14: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 14 97811C Rev G 09 17 FIG 18 23 20 24 6 18 1 10 22 21 14 15 2 8 13 19 12 7 17 16 9 4 6 3 5 9 5 5 11...

Page 15: ...ter flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file or small diameter wire CAUTION DO NOT file or cut orifice material Stream Regulator If orific...

Reviews: