97811C  (Rev. G - 09/17)

OVLEBPFR, OVLSBPFR, OVLSEBPFR

Halsey Taylor Owners Manual

Non-Refrigerated  Freeze  Resistant  Fountains

Halsey Taylor Fountains are among the easiest to install Fountains on the market 

today. To assure you install this model easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR 

INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER 

APPLICABLE CODES.   After  installation, leave  these  instructions  with  the  Fountain  

for  future   reference.  This  Freeze  Resistant  Fountain(s) is shipped in two separate 

cartons.  The second carton(s) contains the Freeze Resistant Package(s) 

HTFRB1

 

that are installed on an interior heated wall.  The interior space must maintain a 

minimum temperature of 50° F (10° C).  Refer to the Freeze Resistant Package for 

the rough-in dimensions for installation.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

OVLEBPFR

OVLSBPFR

OVLSEBPFR

IMPORTANT!  INSTALLER  PLEASE  NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC.  TO WATER LINES 

IS  A  COMMON PROCEDURE.  THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM 

THE BUILDING.  THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO  A  FOUNTAIN, CREATING  AN 

ELECTROLYSIS WHICH CAUSES  A  METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE 

WATER. THIS CONDITION  IS  AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED.   ANY DRAIN 

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE 

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

Installer

Summary of Contents for OVLEBPFR

Page 1: ...interior heated wall The interior space must maintain a minimum temperature of 50 F 10 C Refer to the Freeze Resistant Package for the rough in dimensions for installation IMPORTANT ALL SERVICE TO BE...

Page 2: ...Tighten securely 5 Assemble the operating cable to the fountain bracket Fountain should be mounted to exterior wall The adjustment nuts should be in the middle of threaded area on the operating cable...

Page 3: ...PAGE 3 97811C Rev G 09 17 OVLEBPFR OVLSBPFR OVLSEBPFR FIG 1 FIG 2 TOP VIEW ROUGH IN FOR OVL SBPFR OVL EBP FR...

Page 4: ...mm 43 5 8 1108mm 6 152mm 16 406mm 5 1 4 133mm 5 1 4 133mm FINISHED FLOOR 8 203mm 1 2 13mm 1 25mm 3 8 DIA 10 10mm B A BACK PANEL WALL PLATE ASSEMBLY D 1 1 4 32mm C 2 X 3 1 2 SLOT FOR A B C STUDS REQUIR...

Page 5: ...mm 43 5 8 1108mm 1 25mm 1 2 13mm 5 1 4 133mm 5 1 4 133mm 8 203mm 8 203mm 1 1 4 32mm 6 152mm 16 406mm STUDS REQUIRED FOR FRAME WALL CONSTRUCTION BACK PANEL WALL PLATE ASSEMBLY A B C D 2 X 3 1 2 SLOT FO...

Page 6: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 6 97811C Rev G 09 17 12 305mm MAX WALL THICKNESS 7 1 4 184mm 7 1 4 184mm 12 1 8 308mm 12 1 8 308mm FIG 5 TOP VIEW ROUGH IN FOR OVL SEBPFR...

Page 7: ...8 67mm 3 5 8 92mm 12 305mm MAX WALL THICKNESS 14 1 4 362mm 15 5 16 389mm 19 3 16 488mm 20 1 4 514mm 21 5 16 541mm 25 3 16 640mm FINISHED FLOOR 28 11 16 728mm 34 11 16 880mm 25 3 4 654mm 28 11 16 728mm...

Page 8: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 8 97811C Rev G 09 17 7 1 4 184mm 12 1 8 307mm 12 305mm MAX WALL THICKNESS TOP VIEW ROUGH IN FOR OVL EBPFR WITH MPW100 MOUNTING PLATE FIG 7...

Page 9: ...VL EBPFR WITH MPW100 MOUNTING PLATE FIG 8 28 11 16 728mm 27 686mm ADA REQUIREMENT 7 1 16 180mm 43 7 8 1114mm 28 11 16 729mm 1 25mm 1 1 4 32mm 1 2 13mm 1 7 8 47mm 8 203mm 16 406mm 8 203mm MPW100 MTG PL...

Page 10: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 10 97811C Rev G 09 17 7 1 4 184mm 12 1 8 307mm 7 1 4 184mm 12 1 8 307mm 12 305mm MAX WALL THICKNESS TOP VIEW ROUGH IN FOR OVL SEBPFR WITH MPW200 MOUNTING PLATE FIG 9...

Page 11: ...8 454mm 28 11 16 728mm 33 838mm 14 1 4 362mm 13 1 4 337mm 17 3 4 451mm 34 11 16 881mm 20 1 4 515mm 23 3 4 604mm 27 686mm ADA REQUIREMENT 2 5 8 66mm 3 5 8 91mm MPW200 MTG PLT REF SEPARATE INSTALLATION...

Page 12: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 12 97811C Rev G 09 17 CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play FIG 11 FIG 12 FIG 13...

Page 13: ...ET NOTE WATER FLOW DIRECTION BUILDING WATER INLET 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY SERVICE STOP NOT FURNISHED FIG 14 FIG 17 FIG 16 SEE FIG 8 SEE FIG 13 Installing Back Panel When...

Page 14: ...OVLEBPFR OVLSBPFR OVLSEBPFR PAGE 14 97811C Rev G 09 17 FIG 18 23 20 24 6 18 1 10 22 21 14 15 2 8 13 19 12 7 17 16 9 4 6 3 5 9 5 5 11...

Page 15: ...ter flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file or small diameter wire CAUTION DO NOT file or cut orifice material Stream Regulator If orific...

Reviews: