1000002449 (Rev. E - 04/18)
OVLEBPWSI_NF OVLEBPWSI_WF
Page 4
Figure 4 - Upper Panel Installation
Figure 5 - Fountain Installation
33, 34, 35, 36, 37
17
8.
Install fountain
with (4) 5/16-18 HHMS (provided) (Fig 5).
Connect the ¼” water line from the fountain to the remaining
opening on the tee (cut line to fit as needed).
9.
Attach waste tubes
(1-1/4” O.D.) to 1-1/4” O.D. slip trap.
Trap on the bottle filler side must be 1-1/2” O.D. (provided by
others).
10.
Make final water supply connections.
11.
These products are designed to operate on 20-105 PSI
supply line pressure.
If inlet pressure is above 105 PSI, a
pressure regulator must be installed in the supply line.
(
Caution:
Any damage caused by connecting these products
to a supply line with pressure lower than 20 PSI or higher
than 105 PSI IS NOT covered under warranty.)
12.
Make electrical connections
to the bottle filler. The LCD
Bottle counter should illuminate.
13.
Verify proper dispensing
from the bottle filler by placing a
cup, hand or any opaque object in front of sensor area and
verify water dispenses.
Note:
the first initial dispenses might
have air in the line which may cause a sputter. This will be
eliminated once all air is purged from the line. A steady stream
of water assures all air is removed. The sensor has a 20
second maximum ON time. It may be necessary to step away
from the beam a few times to purge all air. Check for leaks.
14.
Check stream height from bubbler.
Stream height is factory
set for 35-40 PSI supply. If supply pressure varies greatly from
this, remove items 6,7, and 8) (push arm and the bottom and
the top actuator plates - (Figure 8) by removing the screws
holding assembly together and adjust the screw on the regula-
tor (Item 19 - Figures 7 & 9). Clockwise adjustment will raise
stream height and counterclockwise movement will lower
stream height. For best adjustment, stream height should be
approximately 6-1/2” (38mm) above the bubbler guard.
Reassemble the pushbar (Fig 8).
15.
Install the cover plates.
2
5
18
4
NOTE:
When installing replacement bubbler and pedestal
(Fig 6), tighten locknut only to hold parts snug in position.
Do Not overtighten.
Figure 6 - Bubbler Detail
1
Locknut
3
10
20
20
26
Reset
Switch
9
Back
Panel