background image

1000002450  (Rev. C - 06/16)

OVLERWSI_NF    OVLERWSI_WF

Page 6

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall 

    outlet. 

4)  Restart the unit by plugging the power cord back into the wall 

    outlet.

5) Upon start up, the bottle count display will show the software 

    designation of BF11.

6) Reference the BF11 instructions for setting the control board.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button remove the top cover of the bottle-

    filler. Remove the two (2) screws holding top cover to bottle-

    filler with a 5/32” allen wrench.  Remove top cover. Do not discard 

    mounting screws, they will be needed to reinstall the top cove

 

after 

    programming operations are completed. The programming button 

    is located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting, 

  "1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll 

    through two messages:

       “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

       “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

    display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display 

    will show the new value.  (Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate   1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for approximately 

  9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oak Park Dr., Unit A, Mooresville, NC 28115

Summary of Contents for OVL HTHBWF-OVLER-I

Page 1: ...electrolysis effect occurring in the fountain This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water When inspecting plumbing circ...

Page 2: ...WALL 5 8 16mm 17 15 16 455mm 1 1 2 38mm 1 1 4 32mm WASTE TUBE FURNISHED BOTTLE FILLER DRAIN ACTIVATION SENSOR ELECTRICAL INLET 3 8 O D COPPER TUBE WATER INLET ON CHILLER SHUT OFF VALVE BY OTHERS 1 4...

Page 3: ...of chiller A minimum of 4 102 mm on both sides top is required See chiller installation for additional instructions 5 Hang main panel on mounting frame hanger Make sure the power cord reset switch wir...

Page 4: ...ote the first initial dispenses might have air in the line which may cause a sputter This will be eliminated once all air is purged from the line A steady stream of water assures all air is removed Th...

Page 5: ...ly 6 8 7 Figure 8 Push Bar Mechanism 21 11 22 19 Figure 9 Regulator Assembly Regulator Mounting Bracket See Figure 7 Figure 11 Water Supply Connections NOTE WATER FLOW DIRECTION BUILDING WATER INLET S...

Page 6: ...ow 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capac...

Page 7: ...14 1 2 3 3 ITEM NO Filter Assy 3000 Gal Kit Filter Head Fittings Includes John Guest Fittings Assy Filter Brkt includes Fltr Head Mtg Bkt John Guest Fittings Screws 1 2 3 55898C 98926C 51469C DESCRIP...

Page 8: ...th Back Panel Strainer Provided with Chiller Slip Nut Lower Panel Screw 10 24 x 62 HHSM Screw 10 24X 50 PHTC Regulator Screw 5 16 18 x 1 00 HHMS Hex Nut Regulator Holder Bumper Regulator Valve Assy Re...

Reviews: