INSTALLATION INSTRUCTIONS

1. This fountain is to be mounted on a smooth, flat, finished wall surface, with adequate support structure.

2. Establish rim height fountain is to be mounted.

3. Refer to rough-in for plumbing.

4. Locate and install trap. (Trap not furnished.)

5. Install shut-off valve on building water supply. (Shut-off valve not furnished.)

6. Remove access panel from bottom of fountain.

7. Locate and install fountain using 3/8" (10 mm) (minimum) lag screws or bolts (not furnished).

    CAUTION: 

This fountain is rated for inlet water pressure of 20-90 PSI. Should the inlet water supply exceed 90 PSI,

    a pressure reducing regulator should be used.

8. Connect fountain to building supply line with a shut-off  valve and install a 3/8" (10 mm) unplated copper water

    line between the valve and fountain. Remove any burrs from outside of water line. Insert water line to a positive

    stop, approximately 3/4" (19 mm) on inlet side of strainer. 

DO NOT SOLDER TUBES INSERTED INTO THE

    STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.

9. To remove waste elbow, remove (4) screws (item 18) and drop bottom plate (item 20) and push bar (item 2)

    down. Waste elbow slip nut (item 13) is now accessible. Connect fountain drain.

10. Turn “ON” water supply and check all connections for leaks.

11. Adjust projector stream height.

12. If needed, adjust push arm/regulator clearance by turning phillips head screw (item 26) on regulator bracket

      assy. (item 30). Turning screw CCW should correct water coming out of projector continuously.
13. Reinstall access panel using screws provided.

         

 TROUBLE SHOOTING AND MAINTENANCE

Orifice Assy:

 Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be

      removed from the orifice with a small round file or small diameter wire.

      

CAUTION: DO NOT

 file or cut orifice material.

Stream Regulator: 

If orifice is clean, regulate flow as in instructions above. If replacement is necessary,  see parts

      list for correct regulator part number.

Actuation of Quick Connect Water Fittings:

 Fountain is provided with lead-free connectors which utilize an o-ring

      water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on

      the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately

      3/4".

CAUTION:

  Cleaning of Aztec Gold Models requires special care.  Outer surfaces must be cleaned with a mild

      detergent or mixture of vinegar and water only, rinsed and wiped dry.  Abrasive and acidic cleaners may

      eventually damage the Aztec Gold finish.

Fig. 5

23

24

15

14

Regulator

Mounting Bracket

CARE AND MAINTENANCE OF HALSEY TAYLOR MARBLYTE FOUNTAINS

Marblyte provides an extremely durable , non-porous surface which resists staining. Care is very simple. Routine

cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally

needed to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the

surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth. Harsh abrasive

cleaners are not required and should not be used. Mild abrasives such as liquid automotive cleaning compound

or baking soda paste will remove simple scratches and stains. Cigarette burns can normally be removed without

noticeable effect. Deeper scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a

green scotchbrite pad. To maintain or regain luster and make cleaning easier, periodic applications of automobile

wax or like products will keep the finish looking like new.

Reviews: