background image

HVRGRN8WS*1C     HVRGRN8WSNF*1C

1000001739  (Rev. P - 03/23)

Page 6

7/16” BOLT  HOLES FOR  

FASTENING UNIT TO WALL

UNIT CENTER LINE

Fig. 7

TOP COVER

MOUNTING 

SCREWS

Fig. 8

31

Fig. 10

Fig. 9

BRACKET & SCREWS

Bottle Filler Installation Instructions

1) 

Remove two (2) mounting screw

s with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 8). Remove top cover. Note do not discard mounting 

screws, they will be needed to reinstall top cover. 

2) 

Remove wall mounting plate from Bottle Filler

. Place wall plate against wall on top of basin. Center the wall plate side to side with the basin. Mark 

the six (6) mounting holes with a pencil (See Fig. 7). 

3) 

Remove wall mounting plate from wall

NOTE

: Mounting plate 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate 

support. 

4) 

Install wall mounting plate to wall 

using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 7). Use appropriate fasteners for 

your wall type. 

5) 

Feed power cord & 3/8” water line

 through hole in tower/basin gasket (See Fig 9).

6)

 Install gasket on bottom of bottle filler tower

 with gasket support bracket & (2) screws (See Fig 10). 

7) 

Lay Bottle Filler on water cooler basin

 and cut insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube, but do not discard. 

Feed the power cord and waterline through the hole on top of water cooler. NOTE: To prevent scratching the basin place a towel or soft 

cloth over the entire basin when working above it. 

8) 

With the power cord and waterline through hole

 on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall 

mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 11). 

9) 

Once Bottle Filler is installed on wall plate tabs,

 water line and power cord are installed properly, push top of Bottle Filler toward 

wall and line up top cover two (2) holes. 

10) 

Reinstall Top Cover on Bottle Filler

 (See Fig. 8) with two mounting screws from step 1 above. Caution, do not over tighten screws. 

11) 

Install remaining tube insulation 

to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line to the tee. 

12)

 Install filter cartridge

, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter 

clockwise. NOTE: If existing plumbing rough in locations (Drain, Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet 

the filter can be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler. 

13) 

Turn water supply on 

and inspect for leaks. Fix all leaks before continuing. 

14) 

Once unit has been inspected for leaks

 and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or 

switch the circuit breaker back to the “ON” position. 

15) 

Once power is applied to Bottle Filler,

 the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter. 

16) 

Verify proper dispensing by placing cup

, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses 

might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line. 

17) 

Once unit tests out

, install Lower Panel back on water cooler(s). Unit is now ready for use.

Summary of Contents for HVRGRN8WSNF 1C Series

Page 1: ...ooler Estaci n de llenado de botella Hydroboost y enfriador Station de remplissage de bouteille Hydroboost et refroidisseur Owners Manual WARNING Cancer and Reproductive Harm www P65Warnings ca gov AD...

Page 2: ...red is unit only without bottle filler Uses HFC 134A refrigerant Usa refrigerante HFC 134A Utilise du fluide frigorig ne HFC 134A Note Danger Electric shock hazard Disconnect power before servicing un...

Page 3: ...NPLATED CONNECTE STUB AVEC ETEINT PAR LES AUTRES 3 dans 76 mm le MAXIMUM HORS DU MUR B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACI N RECOMENDADA PARA EL DRENA...

Page 4: ...r como se indica en la figura 4 5 Afloje los dos 2 tornillos que sostienen la parte inferior del panel en la parte inferior de la base del enfriador y los dos 2 tornillos en la parte superior Quite el...

Page 5: ...HVRGRN8WS 1C HVRGRN8WSNF 1C 1000001739 Rev P 03 23 Page 5 Fig 5 26 2 2 2 25 2 2 1 PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE M CANISME DU BOUTON POUSSOIR 2 27 11 10 Fig 6 22 16 21 21 4...

Page 6: ...wall mounting plate installed on wall Make sure round boss in gasket fits in hole of basin See Fig 11 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installed prop...

Page 7: ...will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the butto...

Page 8: ...Guest DESCRIPTION PART NO Ens filtre 3000 Gallon Kit filtre raccord de t te comprend Raccords John Guest Assembl e filtre t te Support inclut John Guest vis DESCRIPTION FILTER PARTS LIST See Fig 14 L...

Page 9: ...11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 DESCRIPCI N 22897C 1000001906 28551C 1000001676 35870C 0000000768 0000002062 1000001602 98750C 98530C 55931C 98775C 56092C 98899C 55996C 984...