97715C (Rev. D - 02/18)
HRFGEBP_A, HRFGSBP_A
Page 3
1.
Wall should already be framed for the fountain
using the positioning dimensions shown in Fig 3. Shown
dimensions pertain to installation location (framing must support up to 150 lbs. weight).
2.
Install rough-in plumbing
as shown in Fig 3. Run supply water inlet line and connect to a service stop (not
provided). Turn on supply water and flush thoroughly. Close water supply.
3.
Remove bottom access panel
from fountain basin and save the screws. Install the fountain to the back
panel and wall using (4) 5/16" bolts and washers (not provided). Bolts should be long enough to securely
fasten the fountain to the wall. Tighten securely, but do not over tighten. Over tightening will crack the
Marblyte Fountain.
4.
Remove elbow from end of p-trap
(item 1) and attach it to drain tube. Re-attach elbow to p-trap and cut
waste tube to required length using plumbing hadware and trap as guide.
5.
Make water supply connections
from service stop to the fountain strainer (item 16) by inserting the water
inlet line into the inlet side of strainer until it reaches a positive stop about 3/4", (See Fig 1, Page 1). Turn
on water supply and check for leaks. Newly installed water supply line should be insulated after leak check
is completed.
DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE
O-RINGS MAY RESULT.
6.
These products are designed
to operate on 20-105 PSI supply line pressure. If inlet pressure is above 105
PSI, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting
these products to supply line pressure lower than 20 PSI or higher than 105 PSI is not covered by warranty.
7.
Check stream height from bubbler.
Stream height is factory set at 45-50 PSI. If supply pressure varies
greatly from this, adjust the screw on regulator item 3 (See Figure 5) by using a small screwdriver through
the small hole in the push button item 8 (See Fig 5). Clockwise adjustment will raise stream height and
counter-clockwise adjustment will lower stream height. For best adjustment stream height should be
approximately 1-1/2" (38mm) above the bubbler guard (See Fig 7, Page 6).
8.
Replace bottom access panel
to fountain basin using screws provided. Tighten securely.
INSTALLATION INSTRUCTIONS
MARBLYTE BACK PANEL
Care and Maintenance of Halsey Taylor Marblyte Fountains
Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very simple. Routine
cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally
needed to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the
surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth.
Harsh abrasive cleaners are not required and should not be used.
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches
and stains. Cigarette burns can normally be removed without noticeable effect. Deeper scratches or gouges can
be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite pad.
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like products
will keep the finish looking like new.
Orifice Assy:
Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice
with a small round file not over 1/8" diameter or small diameter wire.
CAUTION: DO NOT
file or cut orifice material.
Stream Regulator:
If orifice is free of material deposits, regulate flow as in instructions on page 3 (Step 7) or page 5 (Step 9). If replace
-
ment is necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings:
Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove
tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(See Figure 2, Page 1). To insert tubing,
push tube straight into fitting until it reaches a positive stop, approximately 3/4".
CAUTION: Cleaning of Aztec Gold Models requires special care.
Outer surfaces must be cleaned with detergent or mixture of vinegar
and water only, rinsed and wiped dry. Abrasive and acidic cleaners may eventually damage the Aztec Gold finish.
TROUBLE SHOOTING & MAINTENANCE