background image

97715C  (Rev. D - 02/18)

HRFGEBP_A, HRFGSBP_A

Page 3

1.  

Wall should already be framed for the fountain

 using the positioning dimensions shown in Fig 3. Shown    

  dimensions pertain to installation location (framing must support up to 150 lbs. weight).

2.  

Install rough-in plumbing

 as shown in Fig 3. Run supply water inlet line and connect to a service stop (not   

  provided). Turn on supply water and flush thoroughly. Close water supply.

3.  

Remove bottom access panel 

from fountain basin and save the screws. Install the fountain to the back 

     panel and wall using (4) 5/16" bolts and washers (not provided). Bolts should be long enough to securely 

     fasten the fountain to the wall. Tighten securely, but do not over tighten. Over tightening will crack the 

     Marblyte Fountain.

4.  

Remove elbow from end of p-trap

 (item 1) and attach it to drain tube.  Re-attach elbow to p-trap and cut    

  waste tube to required length using plumbing hadware and trap as guide.

5.  

Make water supply connections

 from service stop to the fountain strainer (item 16) by inserting the water    

  inlet line into  the inlet side of strainer until it reaches a positive stop about 3/4", (See Fig 1, Page 1). Turn   

  on water supply and check for leaks. Newly installed water supply line should be insulated after leak check    

  is completed. 

DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE

  O-RINGS MAY RESULT.

6.  

These products are designed 

to operate on 20-105 PSI supply line pressure. If inlet pressure is above 105  

  PSI, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting    

  these products to supply line pressure lower than 20 PSI or higher than 105 PSI is not covered by warranty.

7.  

Check stream height from bubbler.

 Stream height is factory set at 45-50 PSI. If supply pressure varies  

 

  greatly from this, adjust the screw on regulator item 3 (See Figure 5) by using a small screwdriver through    

  the small hole in the push button item 8 (See Fig 5). Clockwise adjustment will raise stream height and  

 

  counter-clockwise adjustment will lower stream height. For best adjustment stream height should be 

  approximately 1-1/2" (38mm) above the bubbler guard (See Fig 7, Page 6).

8.  

Replace bottom access panel 

to fountain basin using screws provided. Tighten securely.

INSTALLATION INSTRUCTIONS

MARBLYTE BACK PANEL

Care and Maintenance of Halsey Taylor Marblyte Fountains

Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very simple. Routine 

cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally 

needed to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the 

surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth.

Harsh abrasive cleaners are not required and should not be used.

Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches 

and stains. Cigarette burns can normally be removed without noticeable effect. Deeper scratches or gouges can 

be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite pad.

To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like products 

will keep the finish looking like new.

Orifice Assy:

 Mineral deposits on orifice can cause water flow to spurt or not regulate.  Mineral deposits may be removed from the orifice 

with a small round file not over 1/8" diameter or small diameter wire. 

CAUTION: DO NOT

 file or cut orifice material.

Stream Regulator:

 If orifice is free of material deposits, regulate flow as in instructions on page 3 (Step 7) or page 5 (Step 9).  If replace

-

ment is necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings:

 Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove 

tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(See Figure 2, Page 1).  To insert tubing, 

push tube straight into fitting until it reaches a positive stop, approximately 3/4".

CAUTION: Cleaning of Aztec Gold Models requires special care.  

Outer surfaces must be cleaned with detergent or mixture of vinegar 

and water only, rinsed and wiped dry.  Abrasive and acidic cleaners may eventually damage the Aztec Gold finish.

TROUBLE SHOOTING & MAINTENANCE

Reviews: