97096C (Rev. D - 9/99)

HRF - ER*B   HRF - SR*B   HRF - SER*B

PAGE 4

PART NO.

ITEM NO.

PARTS LIST

Drain

Drain-Aztec Gold

Retaining Nut

Strainer

Strainer-Aztec Gold

Tailpipe Ferrule

Tailpipe Ferrule-Aztec Gold

Push Button

Push Button-Aztec Gold

Push Button Sleeve

Push Button Sleeve-Aztec Gold

Regulator Holder

Bubbler

Bubbler-Aztec Gold

Regulator

Setscrew #6-32 x .31"

Screw #8-32 x .25"

Strainer

Fountain Arm-Short

Fountain Arm-Short Aztec Gold

Fountain Arm-Extended

Fountain Arm-Extended Aztec Gold

Bottom Cover Plate-Short

Bottom Cover Plate-Extended

Back Panel HRF-SER

Back Panel HRF-SER Aztec Gold

Back Panel HRF-ER/SR

Back Panel HRF-ER/SR Aztec Gold

Hex Nut

Speed Nut

Bracket-Regulator Mounting

Lower Panel HRF-SER

Lower Panel HRF-SER Aztec Gold

Lower Panel HRF-ER/SR

Lower Panel HRF-ER/SR Aztec Gold

Union - 3/8" x 1/4"

Union - 3/8"

Tee - 3/8"

Assy-Bubbler Nipple

Tube-Poly 1/4 x .040 Wall

LK464

LK464AG

15005C

40038C

45364C

40619C

45360C

45662C

45408C

45663C

45411C

50986C

51544C

45396C

61313C

70022C

70426C

55996C

55001035

27571C

55001038

27573C

55000661

55000665

26839C

27542C

26837C

27539C

40045C

70055C

27057C

27026C

27580C

26833C

27578C

70745C

70870C

70852C

15008C

55994C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

DESCRIPTION

FIG. 5

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

SEE FIG. 6

SEE

FIG. 5

8

15

13

12

1

11,14,17

3,4

19

FIG. 6

Orifice Assy:

 Mineral deposits on orifice can cause water flow to spurt or not regulate.  Mineral deposits may

be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.

CAUTION: DO NOT

 file or cut orifice material.

Stream Regulator:

 If orifice is clean, regulate flow as in “

START UP

” instructions.  If replacement is

necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings:

 Cooler is provided with lead-free connectors which utilize an

o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while

pulling on the tubing.(see Fig.2)  To insert tubing, push tube straight into fitting until it reaches a positive stop,

approximately 3/4".

CAUTION: Cleaning of Aztec Gold Models requires special care.  

Outer surfaces must be cleaned with

mild detergent or a mixture of vinegar and water only, rinsed and wiped dry.  Abrasive and acidic cleaners may

eventually damage the Aztec Gold finish.

HRF - ER / SR / SER  COOLER INSTALLATION

1.  Install remote chiller.

 Remove front panel of chiller. Remove and discard cardboard inner pack from

between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides

on the shelf.

NOTE:

 Building construction must allow for adequate air flow on both sides, top, and back of chiller. A

minimum of 4" (102mm) on both sides and top is required. See chiller instructions for additional instructions.

2.  Make water supply connections. 

Attach an unplated copper  water inlet line and a service stop (not

provided) to the chiller. Inlet port is marked on the chiller (3/8" O.D. copper tube). Bend the copper tube

(provided) at an appropriate length from chiller to opening in frame. Install a 3/8" O.D. tube tee fitting (provided)

on the marked chiller outlet port. Turn on the water supply and flush the line thoroughly.

3.  Hang the upper panel on the mounting frame hanger.

 Align holes in the panel with the holes in the

mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it.

4.  Install fountain.

 Remove access cover plate on underside of fountains and save the screws.  Mount the

fountains to the upper panel and the wall frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided).

Tighten securely.

NOTE: 

The short fountain should be mounted to the upper left hand side of the panel.

5.  Remove elbow from end of p-trap

 and attach it to drain tube. Re-attach elbow to p-trap and cut waste

tube to required length using plumbing hardware and trap as a guide.

6.  Make connection between remote chiller outlet tube and fountain strainer.

 Insert the water inlet line

into inlet side of strainer by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). Turn on

water supply and check for leaks. 

DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS

DAMAGE TO THE O-RINGS MAY RESULT.

7.  These products are designed

 to operate on 20-105 PSIG supply line pressure. If inlet pressure is above

105 PSIG, a pressure regulator must be installed in the supply line.  Any damage caused by reason of

connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered

by warranty.

8.  Make electrical connections to the chiller.

 See chiller instructions.

9.  Check stream height from bubbler.

 Stream height is factory set at 45-50 PSI. If supply pressure varies

greatly from this, remove items 5 & 6 and adjust the screw on regulator (item 9). Clockwise adjustment will

raise stream height and counter-clockwise will lower stream height. For best adjustment stream height should

be approximately 1-1/2" (38mm) above the bubbler guard. (See Figure 6)

10. Mount lower panel.

 Loosen  the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip.  Slide upper tongue

of lower panel under lower edge of already installed upper panel.  Tighten previously loosened screws securely.

11.  Replace bottom access panel

 to fountain basin using screws provided. Tighten securely.

TROUBLE SHOOTING & MAINTENANCE

CHILLER

INLET

21

20

CHILLER

OUTLET

12

TO BUBBLER

HRF - ER / SR

TUBE ROUTING

HRF - SER

TUBE ROUTING

TO BUBBLER

TO BUBBLER

12

22

CHILLER

OUTLET

CHILLER

INLET

20

5

6

16

2

9

7

10

18

24

23