background image

24"

       610mm

   CHILD ADA

REQUIREMENT

28 3/8"

721mm

1 1/8"

29mm

11"

279mm

3 1/2"

89mm

4 1/2"

114mm

25 3/16"

640mm

B

C

FINISHED FLOOR

18"

457mm

12"

305mm

MINIMUM DEPTH

BACK WALL LINE

WALL LINE

8 1/8"

206mm

9 3/8"

238mm

1 1/8"

29mm

3 1/8"

80mm

A

19 3/4"

502mm

21 15/16"

557mm

12 1/8"

308mm

3 13/16"

97mm

18 15/16"

481mm

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

1/4” O.D. TUBE 

WATER INLET 

TO COOLER

3/8” O.D. TUBE CONNECT 

COLD WATER SUPPLY

BUILDING WATER 

INLET

NOTE: WATERFLOW 

DIRECTION

SERVICE STOP 

(NOT FURNISHED)

Printed in the U.S.A.

 

®

Page 2

INCREASE HEIGHT BY 3” (76mm) FOR INSTALLATION OF ADULT ADA COOLER

LEGEND:

A = 3/8” O.D. tube connect (Chiller water inlet) shut off valve by others

B = 1-1/4” O.D. waste tube (elbow & trap not provided)

C = Electrical inlet

Contour™ Barrier-Free

(CONTINUED)

WALL OPENING

IMPORTANT: It is necessary to create a wall opening 

18-3/4” W x 37-3/4” H and 4-1/2” above the floor line.

MOUNTING INSTRUCTIONS

Refer to rough-in for location of plumbing and electrical sources. The 

support  frame  is  to  be  installed  first. The  shelf  for  the  water  chiller 

should be assembled to the wall frame, and then place chiller into 

position. Hang upper fountain panel to hanger on frame. Fountain is 

to be attached to panel and wall frame. Water service line, waste line 

and electrical is assembled as required. The bottom panel is attached 

last, after a final check for leaks and correct functions of fountains and 

chiller. (For more details, see the installation instructions.)

Installation requires trap to be installed in wall.  Trap and service 

stop not included.  
OPERATING PRESSURES:

Supply water 20 - 105 psi maximum

ELECTRICAL DATA

Junction box for a (3) wire 10 amp branch circuit.  Standard 120 V, 60 

Hz, single phase. 

 Job Name: ____________________________________

 Model: _____________________________ Qty. ______

  

 Contact: ______________________________________ 

 

 Approval Signature: _____________________________

 Notes:

FRONT VIEW

SIDE VIEW

TOP VIEW

Rated for Indoor Use Only

HCRFER Fountain

with Back Panel